Applications; Technical Data; Table 2: Technical Data; Table 3: Maximum Head (Hmax) And Maximum Flow Rate (Qmax) Of Evosta2, Evosta2D Circulators - DAB EVOSTA2 Instrucciones Para La Instalación Y El Mantenimiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

5. APPLICATIONS

EVOSTA2, EVOSTA2d series circulators allow integrated adjustment of the differential pressure which
enables the circulator performance to be adapted to the actual requirements of the system. This determines
considerable energy saving, a greater possibility of control of the system, and reduced noise.
EVOSTA2, EVOSTA2d circulators are designed for the circulation of:
water in heating and conditioning systems.
water in industrial water circuits.
domestic water only for the versions with stainless steel pump body.
EVOSTA2, EVOSTA2d circulators are self-protected against:
Overloads
Lack of phase
Excess temperature
Over-voltage and under-voltage

6. TECHNICAL DATA

Supply voltage
Absorbed power
Maximum current
Grade of protection
Protection class
TF Class
Motor protector
Maximum environment temperature
Liquid temperature
Flow rate
Head
Maximum working pressure
Minimum working pressure
Lpa [dB(A)]
Designation index
(example)
Series name
2 = without display
2d = with display
Maximum head (feet)
Centre distance (inches)
EVOSTA2, EVOSTA2d
EVOSTA2 110-127V 60Hz
EVOSTA2d 110-127V 60Hz

Table 3: Maximum head (Hmax) and maximum flow rate (Qmax) of EVOSTA2, EVOSTA2d circulators

ENGLISH
110-127V (+/-10%), 60 Hz
See electrical data plate
See electrical data plate
IPX5
F
TF 110
No external motor protector is needed
104 ºF / 40°C
14 ºF ÷ 230 ºF / -10 ºC ÷ 110 ºC
See Table3
See Table3
1.0 Mpa – 145 psi / 10 bar
0.1 Mpa – 14.5 psi / 1 bar
≤ 43

Table 2: Technical data

EVOSTA
Hmax (ft / m)
18 / 5.5
18 / 5.5
4
2
70/
3
Qmax (gpm / m
/h)
16 / 3.6
16 / 3.6
130
Tabla de contenido