Delta Wynne 3534LF Serie Manual Del Usuario página 7

Llaves de lavamanos extendidas de dos manijas
Tabla de contenido
Figure 4
1
W
2a
2c
X
Y
Z
Z
AA
2b
AA
AB
W
AA
* Supplied by others / Fourni par d'autres / Suministrado por otros
STEP 4 - DRAIN ASSEMBLY INSTALLATION
1. Flange Seal:
a. Apply silicone to underside of flange (W). Insert flange (W) into sink drain hole.
2. Drain Install:
a. Install nut (Z), washer (Y) and black gasket (X) onto body drain (AA).
b. Thread the body drain (AA) onto the flange (W) until tight.
 DO NOT turn flange (W) while tightening body drain (AA) or sealant may not seal drain.
c. Tighten the nut (Z) to the under side of the sink.
 DO NOT turn flange (W) while tightening nut (Z) or sealant may not seal drain.
d. Remove excess sealant from around the flange (W) and the sink.
e. Thread the tube drain (AB) into the body drain (AA) until tight.
3. Pivot Rod Install
a. Insert the stopper (V) into the flange (W).
b. The stopper (V) can be installed in two positions:
i. Removable with the stopper (V) rotated 90o and resting on the horizontal rod (AE) (Detail 3a).
ii. Non-removable with the horizontal rod (AE) through the hole in the stopper (V) (Detail 3b).
c. Install washer (AC) and spacer (AD) into the pivot opening.
d. Install the horizontal rod (AE) into the pivot opening.
e. Hand tighten the pivot nut (AF) onto the body drain (AA).
4. Lift Rod Install
a. Attach horizontal rod (AE) to strap (AG) using clip (AH).
b. Install lift rod assembly (AJ) through the faucet body (A) into the strap (AG).

The strap (AG) may need to be bent to allow the lift rod assembly (AJ) to raise and lower the stopper (V). Adjust as required.
c. Tighten screw (AI).
d. Connect assembly to drain (ZB*) (not supplied).
3
AD
AE
AF
3a
3b
V
AE
(see Figure 4)
Page - 7 of 16
4
V
AA
AI
AC
V
AE
A
AJ
AJ
AG
AH
214820, Rev. C
AB
ZB*
Tabla de contenido
loading

Este manual también es adecuado para:

Wynne 3534lf-lpu serie

Tabla de contenido