NITROGEN TEST (N
This operation allows to test the seal of the A/C system using pressurized nitrogen
Selecting NITROGEN TEST the following screen will be displayed:
Connect and open HP and LP coupling to A/C system, then press OK to continue; the following
screen will be displayed:
Connect nitrogen bottle and press OK:
Regulate pressure reducer between 8 and 12 bar and press OK:
The nitrogen will be injected into the A/C system, the test will start as soon as the pressure is
stable:
INSTRUCTIONS MANUAL
)
2
R134a
Connect and open HP and LP coupling to A/C
system press OK
N2 TEST
R134a
Connect N2 bottle
and press OK
N2 TEST
R134a
Regulate pressure reducer
between 8 and 12 bar
and press OK
N2 TEST
R134a
N2 INJECTION
N2 pressure
x.x
bar(rel)
N2 TEST