A3.
CHECK BLOWER MOTOR
ORIENTATION
The blower fan blade opening should be facing the
front of the microwave. You will have to remove the
top cover plate to check the fan blade orientation.
If the fan opening is already facing the front of the
microwave, skip to step A5. Otherwise, continue to
Step A4 to adjust the fan motor orientation.
A4.
ADAPTING BLOWER
FOR RECIRCULATION
NOTE: The exhaust adaptor with damper is not
needed for recirculating models. You may want to
save them for possible future use.
Remove and save screws that hold blower plate
1
to the oven.
Blower Plate Screws
Slide the blower plate from under its retaining
2
flange and lift it off. Remove the cover plate
installed on the back. Remove and save screws
that hold blower unit to the oven.
Retaining
Flange
Carefully pull out the blower unit. The wires
3
will extend far enough to allow you to adjust the
blower unit.
31-7000091 Rev. 2
Installation Instructions
Blower Plate
Back of
Oven
Cover Plate
Blower
Plate
Blower Motor
Screws
Cover Plate
4
Roll the blower unit 90° so that fan blade openings
are facing toward the front of the oven.
BEFORE: Fan Blade
Openings Facing Up
Roll
AFTER: Fan Blade
Openings Facing
Forward