AC AMPS
Range
2mA
200mA
10A
Protection against over charge:
in 2mA to 200mA range: F1: 200mA / 250V fuse
In 10A / 250V range
Maximum current input: mA connector:200mA
10A connector : 10A
Voltage loss : 200mV
Frequency: 40 to 400Hz
Test in 60 / 50Hz
Response: Average response, calibrated in sine wave rms
RESISTANCE (ohms)
Range
200Ohms
2000ohms
20kOhms
200kOhms
2Mohms
20Mohms
Maximum voltage in an open circuit:
in 20Mohm range: 3,0V
Other ranges: <700mV
Protection against over charge: 250VDC or VCA rms in all
ranges
CAPACITANCE
Range
2nF
20nF
200nF
2μF
20μF
Resolution
1μA
0,1mA
10mA
Resolution
0,1Ohms
1Ohm
10Ohms
100Ohms
1kOhm
10kOhms
Resolution
1pF
10pF
0,1pF
1nF
10nF
ENGLISH-6
Accuracy
±1,2 % of rgd ± 5d
±2,0 % of rgd ± 5d
±3,0 % of rgd ± 10d
Accuracy
±1,0 % of rgd ± 10d
±1,0 % of rgd ± 1d
±1,0 % of rgd ± 1d
±1,0 % of rgd ± 1d
±1,0 % of rgd ± 1d
±1,0 % of rgd ± 5d
Accuracy
±4,0 % of rgd ± 3d
±4,0 % of rgd ± 3d
±4,0 % of rgd ± 3d
±4,0 % of rgd ± 3d
±4,0 % of rgd ± 3d