Renfert SILENT TC Manual De Instrucciones página 36

Ocultar thumbs Ver también para SILENT TC:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
5.5.3
Automatic Switch-on for Automatic Operation
Only delivery, the switch-on automatic is set in such a way that operation with the most handpieces is
possible�
EN
If the suction to a connected electrical appliance (e�g� a handpiece) does not react as required (e�g� does
not activate, even though a connected device is in operation) then the switch-on threshold for automatic
operation must be adjusted�
⇒ Press operating mode key (21) for 3 sec�
♦ Starting the programming mode
⇒ Press operating mode key 3 x again�
♦ In the display "c" blinks
⇒ Press Enter key (27)�
♦ Setting the automatic switch-on�
♦ The display will flash alternately "c" (calibration) and "0".
⇒ Switch off electrical devices without standby mode�
⇒ For electrical devices with a standby mode (e�g� handpieces), switch to standby mode (e�g� with a hand-
piece, switch only the control unit on without activating the handpiece)�
⇒ Press the Enter key (27)�
♦ The display will flash alternately "c" (calibration) and "I".
⇒ An electrical device without standby mode must be switched on�
⇒ Operate the handpiece at the speed at which the suction is to be started and run for approx� 3 - 5 sec-
onds (so that overcurrent during start-up is not detected)�
⇒ Press the Enter key (27) (whilst the handpiece is still running)�
♦ An acoustic signal acknowledges the information�
♦ The setting is saved�
♦ Exit programming mode�
For devices with standby mode, these should be switched on approx. 5 minutes before setting to
avoid incorrect measurements.
If there is an error with the switch-on function, the display "C" will blink and an acoustic signal is
emitted twice. Set the changes again.
5.5.4
After-run Time of the Suction Turbine
After-run time = the time between switching off a connected consumer and turning off the suction turbine�
You can select between 5 times (factory setting 3 sec�)�
After-run time / sec.
To change:
⇒ Press operating mode key (21) for 3 sec�
♦ Starting the programming mode�
⇒ Press the operating mode key 4 x�
♦ In the display "t" blinks�
⇒ Press Enter key (27)�
♦ Setting the after-run time is selected�
♦ In the display (24), "t" and a number for the time interval will be shown alternately�
⇒ Set the required time interval with the [+] / [-] keys�
⇒ Press Enter key (27)�
♦ Save changes, exit programming mode�
In order to prevent the suction from being switched on / off too often in the case of short interrup-
tions (for example when working with the handpiece), a higher time value can be selected.
Value in display (24, Fig. 2)
0
3
5
10
20
30
1
2
Factory setting
3
4
5
6
- 12 -
21
27
Fig. 11
21
23
25
27
Fig. 12