1.
Inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are damaged, contact your dealer before using.
2.
Read all the installation instructions regarding installing and start up before performing any of the work described within. Retain for future reference.
SEE BELOW FOR LIST OF WARNINGS
1.
For your protection always disconnect the power supply from its power source
before handling the components of your primary pump.
2.
Sump water is non-potable. To reduce the risk of contamination of the
potable water supply, the Home Guard
listed backflow device suitable for the installation, in accordance with
the local plumbing code, such as a reduced pressure principle backflow
preventer (RP). Alternately, consult the local plumbing and health codes
or the authority having jurisdiction for guidance on cross-connection and
backflow protection requirements.
CAUTION
Turbulence caused by high velocity incoming water can
negatively affect the on/off action of the float mechanism. If this condition
exists, the incoming water must be baffled to avoid excessive turbulence.
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
MODEL 503
WATER POWERED EMERGENCY BACKUP
SUMP PUMP SYSTEM
PVC CONSTRUCTION
PREINSTALLATION CHECKLIST
Max must be installed with a
®
REFER TO WARRANTY ON PAGE 2.
© Copyright 2020 Zoeller

®
SEE BELOW FOR LIST OF CAUTIONS
1.
This pump is designed for handling clear water. Do not use in septic tanks
to pump effluent or sewage pits to pump sewage.
2.
Repair and service of your backup system should be performed by an
authorized service station.
3.
The installation of this backup pump requires the use of a variable level
float switch for operation. It is the responsibility of the installing party, to
ensure that the float switch will not hang up on the pump apparatus or
pit peculiarities and is secured so the pump will turn "on" and "off". It is
recommended that the pit be 18" in diameter or larger to accommodate both
a primary and a backup pump.
4.
Check the installation of the primary and backup pump floats to ensure
that both move freely and are not being encroached upon where the float
cannot move. Adequate space between the floats must be maintained.
5.
The pump should be manually activated once a month by lifting the float
rod. Let the pump run for at least 15 seconds to prevent the pump from
building up calcium deposits and debris, which could harm the pump.
Co. All rights reserved.
®
Visit our website:
zoellerpumps.com
U P
C
C
®
CAUTION
FM2540
0520
Supersedes
0818
Tabla de contenido
loading

Resumen de contenidos para Zoeller Home Guard Max 503

  • Página 1 If this condition exists, the incoming water must be baffled to avoid excessive turbulence. REFER TO WARRANTY ON PAGE 2. © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Página 2 12. DO install a dedicated shut-off valve on the water supply line within 6 ft. (1.8 working properly. m) of the Home Guard Max. ® DO review all applicable local and national codes and verify that the installation conforms to each of them. © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Página 3 3.3) In order for this installation to work properly, a check valve must be installed onto the discharge line. The following Zoeller check valves are recommended: 30-0100; 30-0101; 30-0102; 30-0103. Some local codes require a union check with ball valve. Check your local code requirements to ensure that the installation complies.
  • Página 4 At an eight-foot static head and a supply pressure of 40 PSI at water supply inlet with water flowing, it takes one (1) gallon of supply water to remove one and a half gallons from the sump. As the supply pressure increases with the static head constant, less supply water is required. © Copyright 2020 Zoeller Co. All rights reserved.
  • Página 5 © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Página 6: Performance Characteristics

    Blockage in discharge pipe. Remove pipe and flush out debris. WATER Foot valve above water level. Adjust Float - Refer to STEP 2. Vertical lift too high. Change discharge piping or contact technical service. © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Página 7: Illustrated Parts Breakdown

    150554 150554 Items included in rebuild kit. Foot valve will need to be cut off as close to top of valve as possible and a new one glued in place. SK2741 © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Página 8 MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 Visit our website: (502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624 zoellerpumps.com © Copyright 2020 Zoeller Co. All rights reserved. ®...
  • Página 9 Visite a nuestro sitio web: Registre en línea zoellerpumps.com DIRECCIÓN PARA ENVÍOS: 3649 Cane Run Road • Louisville, KY 40211-1961 EEUU su producto de TEL: +1 (502) 778-2731 • FAX: +1 (502) 774-3624 Zoeller Pump Company: http://reg.zoellerpumps.com/  ® ® MODELO 503...
  • Página 10: Garantía Limitada

    1.8 m (6 pies) del Home Guard MAX. ® EXAMINE todos los códigos nacionales y locales pertinentes y verifique que la instalación se realice conforme a cada uno de ellos. © 2020 Zoeller Co. Todos los derechos reservados. ®...
  • Página 11: Instalación

    Se debe instalar una válvula de retención en la línea de descarga para que la instalación funcione correctamente. Se recomienda utilizar las siguientes válvulas de retención Zoeller: 30-0100; 30-0101; 30-0102; 30-0103. Algunos códigos locales estipulan una válvula de retención de unión con un flotador.
  • Página 12: Paso 5: Verificación Del Funcionamiento De La Bomba

    3.8 litros (1 galón) para extraer 5.6 litros (1.5 galones) de agua del foso. A medida que aumente la presión del suministro de agua, con una carga estática constante, disminuirá la cantidad de agua requerida. © 2020 Zoeller Co. Todos los derechos reservados.
  • Página 13 © 2020 Zoeller Co. Todos los derechos reservados. ®...
  • Página 14: Características De Rendimiento

    La válvula de aspiración está encima del Ajuste el flotador - Refiérase al PASO 2. nivel de agua. La descarga vertical es demasiado alta. Cambie la tubería de descarga o solicite asistencia técnica. © 2020 Zoeller Co. Todos los derechos reservados. ®...
  • Página 15: Desglose De Los Componentes En La Ilustración

    * Artículos incluidos en el juego de reposición. ** La foot valve se debe cortar lo más cerca posible de la parte superior y la válvula nueva se debe fijar con pegamento. SK2741 © 2020 Zoeller Co. Todos los derechos reservados. ®...
  • Página 16 CORREO A: P.O. BOX 16347 • Louisville, KY 40256-0347 EEUU ENVÍOS A: 3649 Cane Run Road • Louisville, KY 40211-1961 EEUU TEL: +1 (502) 778-2731 • FAX: +1 (502) 774-3624 Visite a nuestro sitio web: zoellerpumps.com ® © 2020 Zoeller Co. Todos los derechos reservados. ®...
  • Página 17 Laisser la pompe fonctionner pendant au moins 15 secondes pour l’empêcher d’accumuler des dépôts de calcaire et des débris qui risquent de l’endommager. SE REPORTER À LA GARANTIE À LA PAGE 2 © Copyright 2020 Zoeller Co. Tous droits réservés. ®...
  • Página 18: Garantie Limitée

    12. INSTALLEZ une soupape d'arrêt dédiée sur la conduite d'alimentation en ÉTUDIER tous les codes régionaux et nationaux applicables et vérifier eau à 1,8 m (6 pi) du Home Guard MAX. ® que l’installation est conforme à chacun d’entre eux. © Copyright 2020 Zoeller Co. Tous droits réservés. ®...
  • Página 19 Il faut monter un clapet antiretour sur le tuyau de refoulement pour assurer le fonctionnement correct de la tuyauterie. On recommande les clapets antiretour Zoeller suivants : 30-0100, 30-0101, 30-0102 et 30-0103. Certains codes locaux exigent l’utilisation d’un raccord union à clapet à bille. Vérifier que l'installation est conforme aux exigences des codes locaux.
  • Página 20 5,6 litres (1,5 gallons) d’eau du puisard. Le besoin en eau d’alimentation diminue avec l’augmentation de la pression d’alimentation lorsque la charge statique demeure constante. © Copyright 2020 Zoeller Co. Tous droits réservés. ®...
  • Página 21 © Copyright 2020 Zoeller Co. Tous droits réservés. ®...
  • Página 22: Guide De Dépannage

    OU PAS D’EAU Ajuster le flotteur. Se reporter à l’ÉTAPE 2. niveau de l’eau. Remplacer la tuyauterie de refoulement ou prendre contact avec le service La levée verticale est trop haute. technique. © Copyright 2020 Zoeller Co. Tous droits réservés. ®...
  • Página 23: Vue Éclatée

    * Pièces comprises dans le kit de remise à neuf. ** Il faut couper le clapet de pied aussi proche que possible du haut de la valve et en coller un nouveau à la place. SK2741 © Copyright 2020 Zoeller Co. Tous droits réservés. ®...
  • Página 24 ADRESSE POSTALE : P.O. BOX 16437 • Louisville, KY 40256-0347 USA ADRESSE PHYSIQUE : 3649 Cane Run Road • Louisville, KY 40211-1961 USA Visitez notre site internet : TÉL : +1 (502) 778-2731 • FAX : +1 (502) 774-3624 zoellerpumps.com ® © Copyright 2020 Zoeller Co. Tous droits réservés. ®...