PREASSEMBLED SUMP PUMP SYSTEM WITH BATTERY BACKUP
MODEL 507 - 12 V DC BATTERY BACKUP SYSTEM WITH 120 V AC POWERED SUMP PUMP, MODEL M73
1. Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test/
oil fill plugs from the pump.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future reference.
1. Make certain that the receptacle is within the reach of the pump's power supply
cord. Do not use primary pump circuit. DO NOT USE AN EXTENSION CORD.
Extension cords that are too long or too light do not deliver sufficient voltage
to the pump motor. But, more important, they could present a safety hazard
if the insulation were to become damaged or the connection end were to fall
into the sump.
2. Check to be sure your power source is capable of handling the voltage
requirements of the motor, as indicated on the pump name plate.
3. Make sure the pump electrical supply circuit is equipped with fuses or circuit
breakers of proper capacity. A separate branch circuit is recommended, sized
according to the "National Electrical Code" for the current shown on the pump
nameplate.
4. Testing for ground. As a safety measure, each electrical outlet should be
checked for ground using an Underwriters Laboratory Listed circuit analyzer
which will indicate if the power, neutral and ground wires are correctly connected
to your outlet. If they are not, call a qualified, licensed electrician.
5. For Added Safety. Pumping and other equipment with a 3-prong grounded
plug must be connected to a 3-prong grounded receptacle. For added safety
the receptacle may be protected with a ground-fault circuit interrupter. When
a pump needs to be connected in a watertight junction box, the plug can be
removed and spliced to the supply cable with proper grounding. For added
safety this circuit may be protected by a ground-fault circuit interrupter. The
complete installation must comply with the National Electrical Code and all
applicable local codes and ordinances.
6. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS
POWER SOURCE BEFORE HANDLING. Single phase pumps are supplied
with a 3-prong grounded plug to help protect you against the possibility of
electrical shock. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE
GROUND PIN. The 3-prong plug must be inserted into a mating 3-prong
grounded receptacle. If the installation does not have such a receptacle, it
must be changed to the proper type, wired and grounded in accordance with
the National Electrical Code and all applicable local codes and ordinances.
7. Risk of electrical shock. Do not remove power supply cord and strain relief
or connect conduit directly to the pump.
8. Installation and servicing of electrical circuits and hardware should be performed
by a qualified, licensed electrician.
9. Pump installation and servicing should be performed by a qualified person.
10. Risk of electrical shock. These pumps have not been investigated for use
in swimming pool and marine areas.
11. It is the owner's responsibility to check the battery and battery connection at
least once a month. Batteries contain acid and caution must be taken when
handling.
®
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
INSTALLATION INSTRUCTIONS
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
SEE BELOW FOR
LIST OF WARNINGS
© Copyright 2016 Zoeller
®
507/73
SAFETY INSTRUCTIONS
TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND
OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE PUMP.
This is a SAFETY ALERT SYMBOL. When you see this
symbol on the pump or in the manual, look for one of the
following signal words and be alert to the potential for
personal injury or property damage.
Warns of hazards that CAN cause serious personal injury,
death or major property damage.
Warns of hazards that CAN cause personal injury or
CAUTION
property damage.
Warns of electrical shock hazards that can cause serious
personal injury, death or major property damage.
Identifies any terminal which is intended for connection
to and external conductor for protection against electrical
shock in case of a fault, or the terminal of a protective
earth (ground) electrode.
Read operator's manual.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR
TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
REFER TO CAUTIONS AND WARRANTY ON PAGE 2.
Co. All rights reserved.
®
FM2922
0716
Supersedes
1015
visit our web site:
www.zoeller.com
DATE INSTALLED:
MODEL NUMBER:
NOTICE: VENT HOLE FOR
CHECK VALVE SEE #1 IN
CAUTION SECTION BELOW
Tabla de contenido
loading

Resumen de contenidos para Zoeller 507

  • Página 9: Instrucciones De Seguridad

    . 1 EN LA SECCIÓN PRECAUCIÓN A CONTINUACIÓN. SISTEMA PRE-ENSAMBLADO DE BOMBA DE SUMIDERO RESPALDADO CON BATERÍA, MODELO 507 SISTEMA DE BATERÍA DE RESPALDO DE 12 V CC, CON BOMBA DE SUMIDERO ACCIONADA CON 120 V CA, MODELO M73 INSTRUCCIONES DE INSTALACIÓN LISTA DE VERIFICACIÓN DE PRE-INSTALACIÓN - TODAS LAS INSTALACIONES...
  • Página 10: Garantía Limitada

    Cada año se fabrican millones de baterías, por lo que es imposible garantizar una calidad constante. Una batería defectuosa nunca llegará a cargarse completamente y puede dañar los circuitos de carga del control. Es por ello que Zoeller ofrece su propia línea de baterías. Ofrecemos baterías de agua/de ácido de ciclo profundo y baterías AGM libres de mantenimiento que pueden accionar la bomba de forma continua durante más de 7...
  • Página 11: Selección De Batería

    Use una tubería de descarga grande. de ventilación. El contenedor para agua debe ser de conformidad con los códigos y 11. Instale el soporte de la bomba Zoeller (modelo 10-2421) debajo de la especificaciones pertinentes. bomba para proporcionar un contenedor para el agua de sedimentación.
  • Página 12 © Copyright 2016 Zoeller Co. Todos los derechos reservados. ®...
  • Página 13: Instalación

    CC y 0.5 amperios. Se puede utilizar con un discador automático (como el Zoeller 10-2616), alarma o sistema doméstico de seguridad. 5. Conecte el cable verde del sensor al conector del sensor (figura 3). Lea los documentos del equipo auxiliar para ver más instrucciones.
  • Página 14: Vista En Despiece - Bomba Cc

    017197 Válvula de retención 153531 Acoplamiento y abrazaderas de la manguera 019857 Bomba, M73/115 V (507-0013) 73-0001 T de la tubería de PVC de DN40 (1½ pulg.) [ranurada] 153766 Tubería de DN40 (1½ pulg.) X 254 mm (10 pulg.) 019509...
  • Página 15: Información De Solución De Problemas

    Consulte con la fábrica si la lista de verificación anterior no descubre el problema. No intente reparar ni desarmar la bomba usted mismo. El servicio debe ser llevado a cabo por una estación de servicio autorizada por Zoeller. Vaya a www.zoellerpumps.com/servicestations para encontrar la Estación de Servicio Autorizado de su área.
  • Página 16: Pantalla Lcd Y Funciones Del Teclado

    Algunos de estos subproductos pueden producir un olor a huevo podrido. Además, algunos de estos subproductos pueden provocar que un detector de monóxido de carbono se active falsamente. Con el fin de ayudar a evitar una activación falsa, Zoeller Company recomienda poner la batería lo más alejada posible del detector de CO o, si es necesario, ventilar la batería hacia el exterior.

Este manual también es adecuado para:

M73

Tabla de contenido