When commissioning the X8I, carry out the following
procedures before attempting to start.
It is recommended that an authorized and trained
service technician perform the commissioning.

PHYSICAL CHECKS

1. Before applying power to the X8I, ensure the
power supply connections are correct and secure
and the operating voltage selector is set correctly
for the power supply voltage in use (115Vac or
230Vac (+-10%), 50/60Hz).
2. Open the front panel of the X8I and check the
location of the link wire(s) connected to the
"Voltage Selection" terminals of the power supply
PCB. If necessary, change the link wire locations to
those illustrated for the voltage in use.
See the section on Installation for more
information.
3. Switch on the power supply to the X8I.
4. The control program identification will be
displayed for a short period followed by the normal
operational user display.
SECTION 8  COMMISSIONING

PRESSURE DISPLAY

Check the displayed system pressure. If the pressure is
incorrect, or inaccurate, check the type and range of the
sensor and carry out the pressure sensor commissioning
and calibration procedure. If the display shows an error,
this will need to be corrected before continuing. See the
Operator's Manual for troubleshooting and correcting the
fault/error condition.
X8I QUICK SETUP CONFIGURATION
Before successful basic operation can be established
specific parameters must be entered prior to startup.
Please refer to the X8I Quick Setup Manual for instruction
to accomplish this.

OPTIONAL FEATURES AND FUNCTIONS

Installation requirements may involve the
implementation of additional or optional functions and
features. Please refer to the appropriate Guide or Manual
as required.