5.0 - FIRST START-UP

• Before start-up make sure that all of the instructions on the rating plate, including the direction of flow, are observed;
• After having gradually pressurized the system, check the seal and operation of the solenoid valve, electrically
powering / disconnecting the connector ONLY IF connected to the coil.
IMPORTANT NOTE: Do not use the connector as a switch to close the solenoid valve.
• Make sure the solenoid valve is closed by electrically connecting it.
5.1 - RECOMMENDED PERIODIC CHECKS
• Use a suitable calibration tool to ensure the bolts are tightened as indicated in 3.2;
• Check tightness of the flanged/threaded connections on the system;
• Check tightness and operation of the solenoid valve;
It is the responsibility of the final user or installer to define the frequency of these checks based on the severity of the service
conditions.
6.0 - MAINTENANCE
On completion of the operations described below, repeat the procedure indicated in paragraph 5.
If the coil need to be replaced:
• Before performing any operation, make sure that the device is not electrically powered;
• Since the coil is also suitable to be permanently powered, coil heating in case of
continuous operation is an entirely normal phenomenon. It is advisable to avoid
touching the coil with bare hands after a continuous power supply lasting longer than
20 minutes. In case of maintenance, wait for the coil to cool down or, if necessary, use
suitable protections;
6.1 - COIL REPLACEMENT (see figure on the side)
• Disconnect the coil's power supply cable, requiring replacement, from the system;
• Use a size 14 commercial spanner to loosen the nut (14) completely and remove
it together with the washer (15);
• Remove the coil (2) from the armature assembly (1);
• Insert the armature assembly: the new coil + washer + nut;
• Tighten the nut (max torque = 1,2 Nm);
• Re-wire as indicated in 3.2;

7.0 - TRANSPORT, STORAGE AND DISPOSAL

• During transport the material needs to be handled with care, avoiding any impact or vibrations to the device;
• If the product has any surface treatments (ex. painting, cataphoresis, etc) it must not be damaged during transport;
• The transport and storage temperatures must observe the values provided on the rating plate;
• If the device is not installed immediately after delivery it must be correctly placed in storage in a dry and clean place;
• In humid facilities, it is necessary to use driers or heating to avoid condensation.
• At the end of its service life, the product is to be disposed of separately from other waste (WEEE directive 2012/19/EU)
and in compliance with the legislation in force in the country where this operation is performed.
8.0 - WARRANTY
The warranty conditions agreed with the manufacturer at the time of the supply apply.
For damage caused by:
• Improper use of the device;
• Failure to observe the requirements described herein;
• Failure to observe the regulations pertaining to installation;
• Tampering, modification and use of non-original spare parts;
are not covered by the rights of the warranty or compensation for damage.
The warranty also excludes maintenance work, other manufacturers's assembling units, making changes to the device and
natural wear.
Madas Technical Manual - 3|3.3b - REV. 0 of 10
13
Sep 2019
th
14
15
2
1
M16/RM N.A. EEX
Tabla de contenido
loading

Tabla de contenido