CPV..-GE-ASI-8E8A-...
3.6 Address assignment (top view)
With regard to addressing, valve terminal type CPV..-GE-ASI-
8E8A-... behaves like two individual slaves each with 4 inputs
and 4 outputs (see 3.1). The inputs and outputs are assigned
permanently to the slave.
The following equipment can be fitted to each valve terminal
half:
Equipment in valve slots 1 to 4 resp. 5 to 8
2 double-solenoid valves *) 4 single-solenoid valves
2
4
1
3
1
1
*) Valve plates with 2 valve solenoid coils (e.g. 2 single-solenoid valves,
double-solenoid 5/2-way valves or 5/3-way valves)
1
Address assignment of the solenoid coils for AS-Interface adress n or n+x
If double-solenoid valves are used, the subsequent valve slot
must be fitted with a blank plate or an isolating plate.
22
1 double-solenoid valve *),
2 single-solenoid valves
2
1
2
3
4
1
1
3
4