Model: EQH-70 Built-in Fireplace.
Maximum Power.
Power transmitted to the atmosphere (useful)
Mass of fuel / hour
Average gas temperature
Average CO concentration at 13% O2
Performance
Accepts logs of the following length:
Fumes ring
Metal Chimney
Recommended chimney height
Brickwork chimney, at least (approx.)
Smoke outlet
Minimum draw recommended
Primary Air Control
Weight
Model: EQH-80 Built-in Fireplace.
Maximum Power.
Power transmitted to the atmosphere (useful)
Mass of fuel / hour
Average gas temperature
Average CO concentration at 13% O2
Performance
Accepts logs of the following length:
Fumes ring
Metal Chimney
Recommended chimney height
Brickwork chimney, at least (approx.)
Smoke outlet
Minimum draw recommended
Primary Air Control
Weight
WARNING! Your EQH built-in fireplace should not be used as an incinerator
and no other types of fuel should be used (plastic, coal...). Use
recommended materials only.
Recommended fuel:
Haya
Encina
Pino
Draw = 2 mmca.
(*) In the case of other heights consult your Dealer or the manufacturer
VIII.- TECHNICAL DATA.
LOG (Oak, beechwood...)
LOG (Oak, beechwood...)
Dimensiones L x Ø (approx)
FUEL
EQH-70
50cm x 7cm
50cm x 7cm
50cm x 7cm
EQH-80
60cm x 7cm
60cm x 7cm
60cm x 7cm
30
13,72KW
10,5KW
3,2 kg
307 ºC
0,16
76.5%
520 mm.
175 mm.
175 mm.
5 to 6 metres
200 x 200 mm.
Vertical
12 Pa
Manual regulation
141 kg
17,34 KW
13,2 KW
3,9 Kg
331 ºC
0,16
76,1%
620 mm.
200 mm.
200 mm.
5 to 6 metres
250 x 250 mm.
Vertical
12 Pa
Manual regulation
147 kg