Install Redi-Twist
and Test for Leaks
G
•
Hold the Redi-Twist™ filter as shown
above.
•
Insert filter up into the system head
until the two nozzles seat into the ports.
•
Turn the Redi-Twist™ filter from left
to right (as you face it) until it stops.
•
Turn on the cold water shut-off valve.
•
Turn on the new filter. Allow the
water to run for approximately
10 minutes.
•
Check for any leaks.
•
If system is leaking, turn off cold
water shut-off valve and refer to
troubleshooting guide.
8
Filter
™
Step 4
Align Arrow
1/4 turn
Troubleshooting
Guide
Leaks between system
head assembly and
Redi-Twist™ filter
•
Remove the Redi-Twist™ filter and inspect the
o-rings. Make sure they are in place and free
from dirt and particles.
•
Install the Redi-Twist™ filter.
•
Turn on the cold water supply valve and
turn on the filter faucet.
•
Make sure Redi-Twist™ filter is fully into the
lock position.
•
Turn off the cold water shut-off valve.
Press in the collar on the Inlet and/or Outlet
fittings. Remove tube and inspect. Repair/
replace tubing. Reconnect tubing. Ensure it
hasn't been crimped.
•
Turn the cold water shut-off valve back on and
turn on the faucet for filtered water.
» If leaks continue, turn off the water supply and call
Customer Service or your local plumber.
Leaks around fittings