Troubleshooting Guide - Brita Redi-Twist USS-301 Manual De Instalación

Ocultar thumbs Ver también para Redi-Twist USS-301:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

direct connect to kitchen faucet
Install Redi-Twist
and Test for Leaks
Hold the Redi-Twist™ filter with the
label facing you.
Insert filter up into the system head
until the two nozzles seat into the ports.
Turn the Redi-Twist™ filter from left
to right (as you face it) until it stops.
Turn on the cold water shut-off valve.
Turn on the new filter and faucet.
Allow the water to run for
approximately 10 minutes.
Check for any leaks.
If system is leaking, turn off cold
water shut-off valve and refer to

troubleshooting guide.

8
Filter
Step 3
Align Arrow
1/4 turn
direct connect to kitchen faucet
Troubleshooting
Guide
*
Remove the Redi-Twist™ filter and inspect the
o-rings. Make sure they are in place and free
from dirt and particles.
*
Install the Redi-Twist™ filter.
*
Turn on the cold water supply valve and
turn on the filter faucet.
*
Make sure Redi-Twist™ filter is fully into the
lock position.
*
Turn off the cold water shut-off valve. Press
in the gray collar on the Inlet and/or Outlet
fittings. Remove tube and inspect. Repair/
replace tubing. Reconnect tubing. Ensure it
hasn't been crimped.
*
Turn the cold water shut-off valve back on and
turn on the faucet for filtered water.
*
Turn off the cold water shut-off valve to the
filter system.
*
Locate the kitchen faucet adapter.
- If the 3/8" plastic tubing is leaking,
follow the previous steps.
- If the thread between the kitchen
faucet adapter and the kitchen faucet
stem is leaking, tighten more securely. If
leaking continues, disconnect the 3/8"
plastic tubing and remove the kitchen
faucet adapter. Wrap the kitchen
faucet adapter and the cold water supply
line with plumber's tape and re-install.
- Turn the cold water shut-off valve back
on and turn on the faucet for filtered
water.
» If leaks continue, turn off the water supply and call
Customer Service or your local plumber.
Leaks between system
head assembly and
Redi-Twist™ filter
Leaks around fittings
Leaks on Kitchen
Faucet Adapter
connection