WARNING: Turn power off at the
circuit breaker before wiring.
INSTALLING SENSOR
Removing Control Panel Cover
1. Remove the decorative cover plate (secured
by two small screws).
2. Press in with screwdriver as shown in Figure
2. Swing control panel cover out to remove.
Control Panel
Cover
Figure 2 - Removing Control Panel Cover
Control
Panel
Mode
Selection
Switch
Figure 3 - Connecting Electrical Leads of Sensor
Black
+
5
10
1
15
Test
20
T I M E
L I G H T
Typical Installation
1. Remove existing wall switch from junction
box.
2. Connect electrical leads of sensor as shown in
Figure 3. Before installing sensor into junction
box, make sure there is no wire exposed at
each connection.
3. Mount sensor into junction box using two large
mounting screws provided.
4. For test purposes, use a small screwdriver to
turn the TIME control fully counterclockwise
and the LIGHT control fully clockwise. Turn
the power back on at the circuit breaker.
5. Set mode selection switch to the AUTO posi-
tion. When unit stabilizes (about 1 minute),
the sensor is ready to detect motion. If sensor
detects motion, the lights will turn on. The
lights will turn off 5 seconds after motion is
no longer detected.
To Lighting Load
Lighting Load
Black
2
Neutral
Return
Green ground wire to
junction box screw or
grounding wire.
Line
"Hot"
595-4881-10