Hydraulic Crimping Tool Set | 16 – 400 mm²
SPECIFICATION
Crimping range: 35 - 300 mm² (aluminum teminal)
Crimping range: 16 - 400 mm² (copper terminal)
Max. pressure: 16 T
Max. stroke: 24 mm
Mould sizes: 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm²
Crimping shape: Hexagon
FEATURES
This product can automatically adjust pressure in all directions. It can contact and press steadily with
small resistance and high work efficiency.
INTENDED USE
This is an ideal tool for contact type copper and lead terminals and connection of union pipes used in
electric cable conductors and in other the electric power operations.
OPERATION INSTRUCTIONS
When pressing cables, select cable of the required size and the corresponding contact mould. Install
terminals in the middle of the contact moulds, close the oil valve tightly and turn the movable handle
to enabled plunger pump to start up. While the hydraulic pressure is increasing, the pistons will push
the contact moulds meet. (Do not continue to exert pressure after the two contact moulds meet to
avoid damages to the components.) If there is a pressure relief valve, when the specified pressures is
reached, you will hear a slight hissing sound indicating an automatic release of internal pressure and
the work has been finished. Loosen the oil valve, and the piston will retract automatically. Repeat the
next operation as mentioned above. It is normal to see a slight trace of oil appearing on the outside of
the plunger and the big piston after repeated operations.
REPAIR AND MAINTENANCE
This product has tightly fitted components. Do not dismantle the components. Avoid knocking the tool
and keep it away from moisture. After repeated use of this tool for some time, check the quantity of oil
in the reservoir inside the hand tool. Use hydraulic oil SAE15 for refill. Refilled oils shall be cleared of
dust and grit. Unload the fixed handle, pull out the rear oil plug from the oil reservoir and add hydraulic
oil SAE15 until oil overflows. Loosen the oil valve, turn the movable handle slowly for several times to
release trapped air in the oil reservoir. Replace the oil plug and strew down the fixes handle.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Tel.: 02196 720480
Fax.: 02196 7204820
Art. 9573
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed