Hydrofarm Phantom DE Instrucciones página 7

Ocultar thumbs Ver también para Phantom DE:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

When setting restrike delays with your environmental controller, it is best to set a restrike delay at 20
minutes or longer to prevent constant restrikes throughout the day.
When installing your controller, it is best to program the controller for a staggered start with 40
luminaires or fewer on each start.
It is best to use special HID relays and high inrush circuit breakers to ensure proper performance.
For optimum performance, lighting sub-panels should have a fan installed to prevent high heat of
the sub-panel.
AUTOPILOT PX2 CONTROLLER
NOTE: Phantom LP system uses ANALOG 0–11.5V control protocol.
Please ensure you select ANALOG when using with compatible PX series controllers.
The Autopilot PX2 Controller is designed to work with the Phantom Commercial DE Electronic
Ballast. Follow the PX2 Controller instructions for proper operation and to avoid ballast damage.
Typical setup for the PX2 Digital Lighting Controller is shown below.
RJ Data
Link Cable
RJ Data
Link Cable
RJ14 to RJ14
RJ14 to RJ14
Note: Zone A and Zone B
can be set up in one room,
or in two separate rooms.
Note: Zone A and Zone B
can be set up in one room,
or in two separate rooms.
IMPORTANT: Do not attach data link cables to AC power cable. Always keep low voltage data cables and high voltage AC
power harness as far as possible from each other for stable signal transmission. Avoid coiling data cables as well as AC
harnesses in tight coils. Excess cable should be managed by creating long loops as opposed to tight coils.
IMPORTANT: Do not attach data link cables to AC power cable. Always keep low voltage data cables and high voltage AC
power harness as far as possible from each other for stable signal transmission. Avoid coiling data cables as well as AC
harnesses in tight coils. Excess cable should be managed by creating long loops as opposed to tight coils.
ENVIRONMENTAL CONTROLLERS
Advanced Digital & Analog
Lighting Controller
(APDPX2)
Advanced Digital & Analog
ZONE A
Lighting Controller
(APDPX2)
Controls up to
256 HID fixtures.
ZONE A
ZONE B
Controls up to
Controls up to
256 HID fixtures.
256 HID fixtures.
ZONE B
Controls up to
256 HID fixtures.
RJ
Splitter
RJ
Splitter
7
HID Fixtures
PHANTOM
HID Fixtures
with RJ PX Port
PHANTOM
with RJ PX Port
Fixtures are not shown to scale.
HPS, MH & CMH
LEGEND:
Fixtures are not shown to scale.
RJ Data Link Cable
HPS, MH & CMH
LEGEND:
RJ Splitter
RJ Data Link Cable
RJ14 to RJ14
RJ Splitter
RJ14 to RJ14
Tabla de contenido
loading

Este manual también es adecuado para:

55phdesk12l55phdeok12l

Tabla de contenido