Construct a 2x4 pump
support bracket.
3"
(7.6 cm)
Provide access to
the installed pump
for servicing.
8. Relocate and Mount the Pump
For Drain End Pump Only
IMPORTANT! The following steps are required for custom pump location only.
Relocate the pump next to the customized inlet/outlet connections of the whirlpool harness. The
pump may protrude beyond the rim of the whirlpool.
Remove all protective packaging from around the whirlpool harness. Cut only those cable ties
supporting the harness attachment nuts.
Remove the plugs from the pump inlet and outlet openings. Install the O-rings into the grooves on
the inlet and outlet connector fittings.
Construct a wooden 2x4 pump support bracket as shown above.
Slide the pump and support bracket into place.
Thread the plastic inlet and outlet attachment nuts onto the pump until the O-rings make initial
contact.
Tighten each nut no more than another quarter of a turn. Do not overtighten.
Make sure that the whirlpool harness piping is pitched correctly (down and away, as shown above)
to promote the drainage of water from the pump through the suction fitting. Shim the pump if
necessary to level the pump on the subfloor, but only high enough to allow water to drain out the
suction line when the whirlpool is drained.
NOTE: Do not shim the pump more than 1/2" (1.3 cm). If the pump is raised too high, it will not prime
properly.
Secure the pump support bracket to the subfloor with four screws or lag bolts (not provided).
Sterling
Pump Inlet Attachment Nut with O-Ring
7"
12"
(17.8 cm)
(30.5 cm)
Pump Outlet Attachment Nut with O-Ring
Make sure the piping is pitched down and away
from the pump to ensure proper water drainage.