Maintenance
SPECiFiCATiONS
Starting Wattage
.......................
8,550 watts
Wattage
.............................
5,550 watts
AC Load Current:
At 120Volts .........................
46.2 Amps
At 240Volts
.........................
23.1 Amps
Phase
..................................
l-phase
Rated Frequency
.........................
60 Hertz
Fuel Tank Capacity ....................
5 U.S. gallons
Shipping Weight
..........................
170 Ibs.
GENERAL HAINTENANCE
RECOHHENDAT|ONS
The Owner/Operator
is responsible for making sure that
all periodic
maintenance
tasks are completed
on a timely
basis; that all discrepancies
are corrected;
and that the unit
is kept clean and properly
stored.
NEVER
operate
a
damaged
or defective
generator.
NOTE:
Should you have questions about replacing
components
on your Troy-Bilt generator, please call
1-888-61 1-6708 for assistance.
Engine
Maintenance
See engine operator's
manual for instructions.
I
A CAUTiO.
" Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
, Thoroughly wash exposed areas with soap and water;
KEEP OUT OF REACH OF CHILDREN.
DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OILTO
COLLECTION
CENTERS.
i
Generator
Maintenance
Generator
maintenance
consists
of keeping
the unit clean
and dry. Operate
and store
the unit in a clean dry
environment
where
it will not be exposed
to excessive
dust, dirt, moisture
or any corrosive
vapors.
Cooling air
slots in the generator
must not become
clogged with snow,
leaves or any other
foreign material.
NOTE:
DO NOT
use a garden
hose to clean generator.
Water
can enter
engine fuel system
and cause problems,
in
addition,
if water
enters
generator
through
cooling air slots,
some of the water
will be retained
in voids and cracks of
the rotor
and stator
winding
insulation.Water
and dirt
buildup on the generator
internal
windings
will eventually
decrease
the insulation
resistance
of these
windings.
WARNING
WHEN
ADJUSTING
OR MAKING
REPAIRSTOYOUR
GENERATOR
" Disconnect
the spark
plug wire from the spark plug and place
the wire where
it cannot
contact
spark
plug.
WHEN
TESTING
FOR
ENGINE
SPARK
Use approved
spark plug teste_:
DO NOT check for spark with spark plug removed.
Generator
Cleaning
• Use a damp cloth to wipe exterior
surfaces
clean.
CAUTION
DO NOT expose generator
to excessive moisture, dust, dirt,
or corrosive vapors.
DO NOT insert any objects through cooling slots.
• Use a soft bristle brush to loosen
caked on dirt or oil.
• Use a vacuum
cleaner
to pick up loose dirt and debris.
• Inspect
cooling air slots and opening
on generator.These
openings
must be kept clean and unobstructed.