OWNER'S MANUAL
12E Series Effluent Pump
This submersible pump is designed for use in basins or pumping stations and is suitable for pumping clean
water or effluent gray water with up to 3/4" (19 mm) spherical semi-solids. Do not use the pump in appli-
cations where sewage or any other debris (gravel, sand, floating debris, etc.), abrasives, or corrosives are
present.
The pump motor is equipped with an automatic restart thermal protector and
may restart unexpectedly. Activation of the thermal protector indicates that the
motor is overloaded or overheated, which may be due to application problems,
such as a clogged pump impeller, a switch stuck in the on position, a dry running
of the pump, a air-sealed pump, a short pump cycle, an excessively high or low
voltage supply, or a pump, motor, bearings, or seal that may have reached the
end of its useful life.
This product is covered by a Limited Warranty for a period of 36 months from the
date of original purchase by the consumer. For complete warranty information,
refer to www.LittleGiant.com.
Specifications
Model
12E-CIM
12E-CIA-RF
SAFETY INSTRUCTIONS
This equipment should be installed and serviced by technically qualified personnel who are familiar with
the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply with
national and local electrical and plumbing codes and within Little Giant recommendations may result in
electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product's application, limitations, and potential hazards. Read and follow instructions carefully to
avoid injury and property damage. Do not disassemble or repair unit unless described in this manual.
Refer to product data plate(s) for additional precautions, operating instructions and specifications.
Failure to follow installation or operation procedures and all applicable codes may result in the following
hazards:
Risk of death, personal injury, or property damage due to explosion,
fire, or electric shock.
• Do not use to pump flammable, combustible, or explosive fluids such as gasoline, fuel oil, kerosene, etc.
• Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.
• Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
• When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged or electri-
cally disconnected.
• If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of
power.
• If the disconnect panel is not accessible, contact the electric company to stop service.
HP
Volts
Hz
1/2
115
60
Amps
Watts
FLA
Start
10
18
EN
ON Level
N/A
1100
12" - 15"
English
OFF
Level
N/A
6" - 8"