Gas Requirements
Turn on gas and check all pipe connections (internal
and external) for gas leaks with a non-corrosive
detection fluid.
Purge air in gas service line by operating the tumbler in
the drying mode.
If burner does not light and unit goes into lockout, open
and close the door and restart. Repeat these steps until
burner ignites.
WARNING
Check all pipe connections, internal and
external, for gas leaks using a non-
corrosive leak detection fluid. To reduce
the risk of explosion or fire, DO NOT USE
AN OPEN FLAME TO CHECK FOR GAS
LEAKS! Gas connections should be
checked annually for leakage.
A 1/8 inch NPT plug, accessible for test gauge
connection, must be installed immediately upstream of
the gas supply connection to the tumbler.
44
W314
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
2
3
1
7
1
Gas Line to Tumbler Controls
2
1/8 in. Plug
3
Gas Supply Piping System
4
Gas "T" Fitting
5
Gas Pipe Cap
6
Dirt and Water Vapor Trap
7
Shut-Off Valve
Figure 14
4
6 in. (152 mm)
MINIMUM GAS PIPE
6
5
T378I
T378I
70223701