Exhaust Requirements
D1
D2
L
1
Clearance
NOTE: Where the exhaust duct pierces a combustible wall or ceiling, the opening must be sized per local codes.
2
Outlet Duct Diameter for One Battery Same as Largest Station Used
3
Outlet Duct Diameter for Two Batteries
4
45° Typical
Duct
Station
D1
7 in. (178 mm)
A
10 in. (254 mm)
B
12 in. (305 mm)
C
14 in. (356 mm)
D
16 in. (406 mm)
E
18 in. (457 mm)
F
19 in. (483 mm)
G
20 in. (508 mm)
H
22 in. (559 mm)
I
23 in. (584 mm)
J
24 in. (610 mm)
K
25 in. (635 mm)
L
* Requires 6 inch diameter duct from tumbler to manifold
** Requires 8 inch diameter duct from tumbler to manifold
40
1
2
3
L
K
J
4
25, 30 Pound*
D2
10 in. (254 mm)
14 in. (356 mm)
18 in. (457 mm)
20 in. (508 mm)
23 in. (584 mm)
25 in. (635 mm)
27 in. (686 mm)
29 in. (737 mm)
31 in. (787 mm)
32 in. (813 mm)
34 in. (864 mm)
36 in. (914 mm)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
I
H
G
F
Figure 12
Minimum Diameter
30 Pound Stacked, 35 Pound**
D1
9 in. (229 mm)
12 in. (305 mm)
15 in. (381 mm)
17 in. (432 mm)
19 in. (483 mm)
21 in. (533 mm)
23 in. (584 mm)
24 in. (610 mm)
26 in. (660 mm)
27 in. (686 mm)
28 in. (711 mm)
30 in. (762 mm)
Table 13
E
D
C
B
D2
12 in. (305 mm)
17 in. (432 mm)
21 in. (533 mm)
24 in. (610 mm)
27 in. (686 mm)
30 in. (762 mm)
32 in. (813 mm)
34 in. (864 mm)
36 in. (914 mm)
38 in. (965 mm)
40 in. (1016 mm)
42 in. (1067 mm)
70223701