Technical Data - AEG BBS 12C2 Manual Original

Ocultar thumbs Ver también para BBS 12C2:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15

TECHNICAL DATA

Cordless Drill Driver
Production code.......................................................................
Drilling capacity in steel ...........................................................
Drilling capacity in wood ..........................................................
Wood screws (without pre-drilling) ..........................................
No-load speed, 1st gear ..........................................................
No-load speed, 2nd gear .........................................................
Torque * (1,5 Ah)......................................................................
Torque * (3,0 Ah)......................................................................
Battery voltage.........................................................................
Drill chuck range ......................................................................
Weight according EPTA-Procedure 01/2003 (1,5 Ah) .............
Weight according EPTA-Procedure 01/2003 (3,0 Ah) .............
Noise/vibration information
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K = 3 dB(A)) .......................................
Sound power level (K = 3 dB(A)) ............................................
Always wear ear protectors!
Total vibration values (vector sum in the three axes)
determined according to EN 60745.
Drilling into metal, chuck head
Vibration emission value a
................................................
h,D
Uncertainty K ........................................................................
Screw driving without impact, chuck head
Vibration emission value a
...................................................
h
Uncertainty K ........................................................................
Screw driving without impact, right angle head
Vibration emission value a
...................................................
h
Uncertainty K ........................................................................
Screw driving without impact, offset head
Vibration emission value a
...................................................
h
Uncertainty K ........................................................................
* Measured according to AEG standard N 877318
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given
in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase
the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
WARNING! Read all safety warnings and all
instructions. Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
DRILL DRIVER SAFETY WARNINGS
Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory
may contact hidden wiring. Cutting accessory contacting
a „live" wire may make exposed metal parts of the power
tool „live" and could give the operator an electric shock.
Hold power tool by insulated gripping surfaces, when
performing an operation where the fastener may
contact hidden wiring. Fasteners contacting a "live" wire
may make exposed metal parts of the power tool "live" and
could give the operator an electric shock.
Sawdust and splinters must not be removed while the
machine is running.
When working in walls ceiling, or floor, take care to avoid
electric cables and gas or waterpipes.
Remove the battery pack before starting any work on the
machine.
20
ENGLISH
BBS 12C2
..................... 4430 21 01...
...000001-999999
...........................10 mm
...........................20 mm
.............................6 mm
......................0-400 min
-1
....................0-1500 min
-1
...........................32 Nm
...........................40 Nm
...........................12 V
...........................10 mm
........................1,27 kg
........................1,47 kg
...........................69 dB (A)
...........................80 dB (A)
..........................1,1 m/s
2
..........................1,5 m/s
2
..........................0,6 m/s
2
..........................1,5 m/s
2
..........................0,6 m/s
2
..........................1,5 m/s
2
..........................0,6 m/s
2
..........................1,5 m/s
2
Do not dispose of used battery packs in the household
refuse or by burning them. AEG Distributors offer to retrieve
old batteries to protect our environment.
Do not store the battery pack together with metal objects
(short circuit risk).
Use only System PCLS chargers for charging System PCLS
battery packs. Do not use battery packs from other systems.
Battery acid may leak from damaged batteries under
extreme load or extreme temperatures. In case of contact
with battery acid wash it off immediately with soap and
water. In case of eye contact rinse thoroughly for at least 10
minutes and immediately seek medical attention.
SPECIFIED CONDITIONS OF USE
The battery drill/screwdriver may be used for drilling and
screwdriving for independent use away from mains supply.
Do not use this product in any other way as stated for
normal use.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product
described under "Technical Data" fulfills all the relevant
regulations and the directives 2011/65/EU (RoHs),
2006/42/EC, 2004/108/EC and the following harmonized
standards have been used:
EN 60745-1:2009 + A11:2010
EN 60745-2-1:2010
EN 60745-2-2:2010
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
Winnenden, 2013-06-25
Alexander Krug
Managing Director
Authorized to compile the technical file.
Techtronic Industries GmbH
Max-Eyth-Straße 10
71364 Winnenden
Germany
BATTERIES
New battery packs reach full loading capacity after 4 - 5
chargings and dischargings. Battery packs which have not
been used for some time should be recharged before use.
Temperatures in excess of 50°C (122°F) reduce the
performance of the battery pack. Avoid extended exposure
to heat or sunshine (risk of overheating).
The contacts of chargers and battery packs must be kept
clean.
For an optimum life-time, the battery packs have to be fully
charged, after used.
BATTERY PACK PROTECTION
The battery pack has overload protection that protects it
from being overloaded and helps to ensure long life.
Under extreme stress the battery electronics switch off the
machine automatically. To restart, switch the machine off
and then on again. If the machine does not start up again,
the battery pack may have discharged completely. In this
case it must be recharged in the battery charger.
MAINTENANCE
Use only AEG accessories and spare parts. Should
components need to be replaced which have not been
described, please contact one of our AEG service agents
(see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the machine type printed as well as the six-digit
No. on the label and order the drawing at your local service
agents or directly at: Techtronic Industries GmbH,
Max-Eyth-Straße 10, 71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before
starting the machine.
Remove the battery pack before starting any
work on the machine.
Do not dispose of electric tools together with
household waste material! In observance of
European Directive 2002/96/EC on waste
electrical and electronic equipment and its
implementation in accordance with national law,
electric tools that have reached the end of their
life must be collected separately and returned to
an environmentally compatible recycling facility.
ENGLISH
21
Tabla de contenido
loading

Tabla de contenido