* Refer to gasket
instructions
Gasket
3. Install the Bowl
CAUTION: Risk of personal injury or product damage.
Overtightening the T-bolts may cause breakage or chipping of the
vitreous china.
Install the gasket to the bowl. Refer to the gasket installation
instructions supplied by the manufacturer.
NOTE: For a floor-mounted wall-outlet bowl, an all-wax ring is not
recommended.
Carefully align and set the bowl into position.
Tighten the T-bolts.
Ensure that the gasket is properly sealed.
Install the 1/4" (6 mm) floor bolts.
Assemble the bolt cap bases, washers, and nuts to the floor bolts.
Tighten the nuts. Do not overtighten.
NOTE: If the floor bolts extend more than 1/4" (6 mm) from the top
of the nut, loosen the nut and turn the bolt further into the floor.
Retighten the nuts.
Place the bolt caps over each floor bolt.