Dacor DOB30P977 Serie Manual Del Usuario página 14

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation instructions
Electrical Connection Options Chart
If your home has:
4-wire
½"
(1.3 cm)
3-wire
½"
(1.3 cm)
For Single Ovens
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge solid copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death, fire, or electrical shock.
14 English
Install_DOB30P977_DG68-01308A-00_EN+MES+CFR.indb 14
Go to section:
4-Wire Cable from Home Power Supply
3-Wire Cable from Home Power Supply
4-Wire Cable from Home Power Supply
IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local
codes do not allow grounding through neutral, New Branch circuit installations
(1996 NEC), mobile homes and recreational vehicles, new construction and in
Canada.
1.
A
E
2.
B
F
G
3.
4.
H
5.
C
I
D
Cable from home power
A.
supply
6.
Black wires (normally L1)
B.
C.
Red wires (normally L2)
D.
4-wire flexible conduit from
oven
E.
Junction box
F.
White wires (normally
N-neutral)
G.
UL listed wire connectors
H.
green wires (normally
G-ground)
I.
UL listed or CSA approved
conduit connector
Connect the 2 black wires (B) together
using a UL listed wire connector.
Connect the 2 red wires (C) together
using a UL listed wire connector.
Untwist white wire from green (or bare)
ground wire coming from the oven.
Connect the 2 white wires (F) together
using a UL listed wire connector.
Connect the green (or bare) ground
wire (H) from the oven cable to the
green (or bare) ground wire (in the
junction box) using a UL listed wire
connector.
Install junction box cover.
2020-06-24
10:12:37
Tabla de contenido
loading

Tabla de contenido