Ground/Earth the gun by holding it against
the edge of the metal container while flushing.
Failure to do so may lead to a static electric
discharge, which may cause a fire.
15. Trigger the gun into the metal waste container until the
old solvent is gone and fresh solvent is coming out of the
gun.
16. Lock the gun by turning the gun trigger lock to the locked
position (refer to spray gun manual).
17. Set down the gun and increase the pressure by turning
the pressure control knob slowly clockwise to its highest
setting.
18. Check the entire system for leaks. If leaks occur, turn the
sprayer off and follow the "Pressure Relief Procedure" in
this manual before tightening any fittings or hoses.
19. Follow the "Pressure Relief Procedure" (section 4.7) in this
manual before changing from solvent to paint.
Be sure to follow the Pressure Relief Procedure
when shutting the unit down for any purpose,
including servicing or adjusting any part of the
spray system, changing or cleaning spray nozzles,
or preparing for cleanup.
16
4.5

55-GALLON DRUM SETUP

Follow these steps when drawing material from
i
a 55-gallon drum.
1. Make sure the sprayer is shut off and relieved of all pressure
(follow Pressure Relief Procedure, section 4.7).
2. Make sure the suction tube is not attached to the fluid
pump. If attached, release the brass clamps and remove
the suction tube from the fluid pump.
3. Turn the master power switch ON (l).
4. Press and hold the 'UP' (G) on the lift switch for three
seconds to raise the hydraulic motor/fluid pump assembly.
Release the switch after three seconds and the lift will
automatically raise to its highest position and then stop.
5. Position the bottom of the fluid pump over the container.
If drawing from a sealed container, position the bottom of
the fluid pump over the large bung hole.
The inlet filter (rock catcher) on the bottom of
i
the suction tube will need to be removed when
drawing material from a sealed drum. Unscrew it
from the tube.
6. Carefully lower the suction tube down into the material
and then lift it up and attach it to the bottom of the fluid
pump (Fig. 11, inset). Secure it by closing the brass clamps.
7. Place the bleed tube into the material. Use the smaller
vent hole if using a sealed container.