MAINTENANCE

7
MAINTENANCE
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce
the risk of an injection injury, injury from moving
parts or electric shock.
For more extensive service/repair instructions
i
and parts list information, please refer to Form
No. 2412594, found at www.titantool.com on this
unit's product page.
7.1

DAILY MAINTENANCE

Two daily procedures are required for routine operator
maintenance on this sprayer:
A. Lubricating the upper packings (section 7.2).
B. Cleaning the filter screen (section 6.4).
7.2

LUBRICATING THE UPPER PACKINGS

1. Remove the cover screws and remove the cover (fig. 14,
item 1).
2. Clean out the paint that has seeped past the upper
packings into the packing oil reservoir (2) above the fluid
section.
3. Fill the packing oil reservoir 1/2 full with Piston Lube (P/N
314-480) supplied by the factory. This will extend packing
life.
Do not over-fill the reservoir so that it overflows
i
and drips into the paint.
22
2
1
7.3

MAINTAINING THE HYDRAULIC SYSTEM

Use of Titan's Coolflo™ Hydraulic Fluid is
mandatory in the Hydra hydraulic system. Do
not use any other hydraulic fluid. Use of any
Attention
other hydraulic fluid may seriously damage the
hydraulic system and will void the warranty.
Never add or change hydraulic fluid except in
a clean, dust-free area. Contamination of the
hydraulic fluid will shorten hydraulic pump life
Attention
and may void warranty.
Make sure the unit is on a flat, level surface when
i
checking the hydraulic fluid level.
Make sure the unit is not running when checking
the hydraulic fluid level.
1. Check the hydraulic fluid daily. The hydraulic fluid level
should be in between the two notches on the dipstick (1).
If it is dry, add only Titan Coolflo™ Hydraulic Fluid (P/N
430-361).
HYDRA X
1
Tabla de contenido
loading

Este manual también es adecuado para:

Hydra x 4540 psiHydra x 7230Hydra x 7230 psi24122752412277

Tabla de contenido