Putting into operation
24
Coolstapler - basket stacker with cooling by circulating air
Procedure for setting the springs:
Take care when taking the base basket out and putting it back in.
If handled incorrectly there is a danger of crushing.
When setting springs on sharp edges, pay particular attention to the ends of
the tension springs. Risk of injury.
•
Remove inserted baskets.
•
Lift the base basket evenly and put it down on the appliance. Then grip it
with both hands and put it down in a suitable place.
•
Insert or release setting springs uniformly in all groups of springs.
•
For even guiding of the basket with little friction a symmetrical spring ar-
rangment is necessary between the attachment bars. An asymmetric ar-
rangement of springs within an attachment bar does not pose any problem.
•
Preferably release setting springs. Always leave the base springs inserted
if possible. Always release the springs on the lower fixing.
•
Then put the base basket back in with the basket opening facing upwards.
The steps "Checking the spring setting" (1) and "Changing the spring setting"
(2) must be repeated until the upper edge of the upper stacking basket is in
the region of 15 to 25 mm above the upper edge of the housing.
So long as the basket weight remains unchanged, it is only necessary to set
the dispensing height once.
Since the stacker is designed for maximum loading, the existing spring provi-
sion on the appliance is entirely sufficient for all commercial items of crockery.
If the existing spring provision should be insufficient, additional springs must
be inserted. Please obtain the part numbers from the replacement parts list on
page 30.
Before the appliance is put into operation it must be clean and dry.
During operation unhindered intake and outlet of air must be ensured.The air
intake and outlet slots at the side of the cooling assembly should not be
blocked. The minimum distance from walls or other appliances is 20 cm, that
corresponds to about the width of a hand.
The appliances should not be operated near sources of dust or steam. In spite
of being covered, the products could be contaminated and the operation of the
cooling assembly could be impaired.
Observe the safety instructions from page 20 onwards.
Switch on the appliance
•
Cover the stacking tube with the cover to avoid the condensation of mois-
ture from the air.
The cover is provided with a peripheral plastic seal which is safe in terms
of nutritional physiology and must be placed precisely onto the 4 centring
angles made from nickel chromium steel which are located in the corners
of the stacking tube. If the cover is put on at an angle and then moved to
and fro horizontally in order to find the optimum position, then inevitably the
seal will be destroyed in a short time. This impairs the efficiency of the cool-
ing system, since warm air can now penetrate unhindered into the cold ar-
ea.
•
Close the drain in the base plate firmly with the plug so that the cold air re-
mains in the appliance.
•
Insert appliance plug into a suitable socket with an earth contact.
Only use the plug connection provided for this. The appliance should not
be operated with a damaged connecting lead or other visible damage.