CHARGING STEPS
UNICHARGE 1,5.12
1
2
3
4
UNICHARGE 4.12 ET 8.12
1
2
3
4
5
6
7
8
9
TEST
BOOST CHARGE
EQUALISATION
100%
TEST
REPAIR SB
(max. 4 hours)
REPAIR LB
(max. 9 4 hours)
BOOST CHARGE
EQUALISATION
(4+5 = max. 36
hours)
RECOND.
(UNICHARGE 8.12
only, max. 30min)
CHARGE
DIAGNOSTIC
(1,5 seconds)
100%
(4 hours)
LIFE+/STORAGE
Analyzes the state of charge of the battery.
Fast charging at maximum power (battery charged at 75-
Equalizes the charge on all the elements of the battery
(battery charged at 100%).
Maintains battery charge at 100% (floating).
Analyzes the state of charge of the battery.
Recovers sulphated batteries (prolonged deep discharge).
Analyzes the state of charge of the battery.
Fast charging at maximum power (battery charged at 75-
Equalizes the charge on all the elements of the battery
(battery charged at 100%).
This step is operated when the RECOND mode is selected.
It enables stir the battery in order to avoid stratification.
Checks that the battery is properly charged.
Maintains battery at 100% (floating).
Compensates the natural self-discharge of the battery, with
a pulse charge for longer battery lifespan.
www.uniteck.fr
80%).
80%).
EN