Problem
The air outlet on
the indoor unit is
discharging mist.
Water leaks from
the outdoor unit.
There is noise or
vibration.
The indoor unit
gives off an odor.
The air conditioner
does not emit warm
air.
NOTE
• Some functions may not be supported, depending on the model.
Model
Voltage
VM122H6 NJM0, USM0
220 V~
VM122C6 NJM0, USM0
220 V~ 50/60 Hz
VM121H6 NJM0, USM0
115 V~
VM121C6 NJM0, USM0
115 V~
VM182H6 NKM0, USM0
220 V~ 50/60 Hz
VM182H6 NKM1, USM1
VM182C6 NKM0, USM0
220 V~ 50/60 Hz
VM182C6 NKM1, USM1
VM242H6 NKM0, USM0 220 V~ 50/60 Hz
VM242C6 NKM0, USM0
220 V~
26
Possible Causes
The cooled air from the air conditioner
makes mist.
In the heating operations, condensed
water drops from the heat exchanger.
A clicking sound can be heard
when the unit starts or stops due to
movement of the reversing valve.
Creaking sound: The plastic parts of
the indoor unit creak when they shrink
or expand due to sudden temperature
changes.
Flowing or Blowing sound: This is
conditioner.
Odors (such as cigarette smoke) may
be absorbed into the indoor unit and
When Heating Mode starts, the vane
is almost closed, and no air comes
out, even though the outdoor unit is
operating.
The outdoor unit is in Defrosting
Mode.
Outside temperature is too low.
Cooling
Frequency
Power
NOR. 1 095 W/
NOR. 6,20 A/
50/60 Hz
MAX. 1 280 W
MAX. 7,20 A
NOR. 1 095 W/
NOR. 6,20 A/
MAX. 1 280 W
MAX. 7,20 A
NOR. 1 095 W/
NOR. 9,82 A/
50/60 Hz
MAX. 1 394 W
MAX. 12,13 A
NOR. 1 095 W/
NOR. 9,82 A/
50/60 Hz
MAX. 1 394 W
MAX. 12,13 A
NOR. 1 640 W/
NOR. 7,40 A/
MAX. 1 710 W
MAX. 8,10 A
NOR. 1 640 W/
NOR. 7,40 A/
MAX. 1 710 W
MAX. 8,10 A
NOR. 2 010 W/
NOR. 9,60 A/
MAX. 2 420 W
MAX. 11,46 A
NOR. 2 010 W/
NOR. 9,60 A/
50/60 Hz
MAX. 2 420 W
MAX. 11,46 A
• When the room temperature decreases,
this phenomenon will disappear
• This symptom requires installing a drain
hose under the base pan. Contact the
installer.
• These are normal symptoms. The noise will
stop.
• If the smell does not disappear, you need
contact the service center to clean your
heat exchanger.
• This symptom is normal. Please wait until
the unit has generated enough warm air to
blow through the indoor unit.
• In Heating Mode, ice/frost is built up on the
coils when the outside temperature falls.
This function removes a layer of frost on the
minutes.
•
Heating
Current
Power
Current
NOR. 975 W/
NOR. 5,50 A/
MAX. 1 300 W
MAX. 7,30 A
-
NOR. 975 W/
NOR. 9,12 A/
MAX. 1 327 W
MAX. 11,54 A
-
NOR. 1 500 W/
NOR. 6,82 A/
MAX. 1 800 W
MAX. 8,52 A
-
NOR. 1 890 W/
NOR. 9,10 A/
MAX. 2 500 W
MAX. 11,84 A
-
Corrective Action
-
-
-
-