Especificaciones técnicas
Mensajes de error/advertencia mediante IO-Link
Code
0x4210 (16912)
0x5000 (20480)
0x5111 (20753)
0x6320 (25376)
0xFF91 (65425)
Tab. 21 Events
Code
0x80 (128)
32
Type
Warning
Error
Warning
Error
Notification
Additional Code
0x00 (0)
0x11 (17)
0x12 (18)
0x20 (32)
0x21 (33)
0x22 (34)
0x23 (35)
Name
Overtemperature
Device hardware fault
Primary supply voltage
under-run
Parameter error
Data Storage Upload
Request
Name
Device application error
- no details
Index not available
Subindex not available
Service temporarily not
available
Service temporarily not
available - local control
Service temporarily not
available - device con-
trol
Access denied
Festo — SDAS-MHS — 2020-03a
Description
Device Exchange
Check tolerance
Check data sheet and
values
Description
Service has been refu-
sed by the device appli-
cation and no detailed
information of the inci-
dent is available
Access occurs to a not
existing index
Access occurs to a not
existing subindex
Parameter is not acces-
sible due to the current
state of the device ap-
plication
Parameter is not acces-
sible due to an ongoing
local operation at the
device
Parameter is not acces-
sible due to a remote
triggered state of the
device application
Write access on a read-
only parameter