Maintenance Instructions - L.B.White Guardian AD/AW060 Manual Del Usuario E Instrucciones

Calefactor de aire forzado
Ocultar thumbs Ver también para Guardian AD/AW060:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

WARNING
This heater may be washed only on the external
case assembly provided:
A. The heater is disconnected from the electrical
supply.
B. All access panels are securely closed.
C. Water spray nozzle shall not discharge within
6 feet of the heater.
D. The water pressure does not exceed 45 PSIG
for 10 seconds on each side of heater.
E. The heater is not reconnected to electrical
supply for a minimum of 1 hour or until the
heater is thoroughly dry.
Improper cleaning of the heater can cause
severe personal injury or property damage due to
water and/or cleaning solution:
1. In electrical components, connections and
wires causing electrical shock or component
failure.
2. On gas control components causing corrosion
which can result in gas leaks and fire or explo-
sion from the leak.
Clean internal components of the heater with a
soft, dry brush or cloth, or compressed air.
Guardian LP or Natural Gas Heater

Maintenance Instructions

1. Have your gas supplier check all gas piping
annually for leaks or restrictions in gas lines.
Also, at this time have your gas supplier clean
out the sediment trap of any debris that may
have accumulated.
2. The heater's surrounding area shall be kept
clear and free from combustible materials,
gasoline, and other flammable vapors and
liquids.
3. Regulators can wear out and function improp-
erly. Have your gas supplier check the date
codes on all regulators installed and check
delivery pressures to the appliance to make
sure that the regulator is reliable.
4. Regulators must be periodically inspected to
make sure the regulator vents are not blocked.
Debris, insects, insect nests, snow, or ice on
a regulator can block vents and cause excess
pressure at the appliance.
5. Review all heater markings (ie. warnings,
start-up/shutdown, electrical wiring, diagrams,
etc.) for legibility. Ensure that none are cut,
torn, or otherwise damaged. Any damaged
markings must be replaced immediately by
contacting L.B. White Co., Inc. Markings are
available at no cost.
6. Inspect gas hoses for nicks,cuts, or corroded
fittings. Replace the complete gas
hose assembly if defects are found.
7. Inspect the heater's electrical connections.
Replace any terminals that are corroded.
Owner's Manual • Guardian
15
Tabla de contenido
loading

Este manual también es adecuado para:

Guardian ad/aw100Guardian ad/aw250Guardian aw325

Tabla de contenido