Hanging Instructions; Sediment Trap Assembly - L.B.White Guardian AD/AW060 Manual Del Usuario E Instrucciones

Calefactor de aire forzado
Ocultar thumbs Ver también para Guardian AD/AW060:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Hanging Instructions

1. Assemble eyebolts & chain according to
Fig. 2. Tighten hardward securely. Eyebolts
& chain must be ordered separately.
FIG. 2
EYEBOLT
NUT
FLAT WASHER
CAGE NUT
2. Be sure heater is securely fastened and is hang-
ing level. (Check crosswise and lengthwise.)
3. See Fig. 3 for typical indoor installation. In any
animal confinement building, consideration must
be given to making sure the heater is located
away from the livestock so that livestock cannot
knock the heater, tear it loose from its mounting,
or damage the heater or its gas supply line in
any way. Make sure you observe and obey
minimum clearance distances to combustible
materials as stated in the specification section of
this owner's manual and on the heater itself.
FIG. 3
NOTE: REGULATORS SHOULD ALWAYS BE MOUNTED OUTDOORS. IF
CIRCUMSTANCES FORCE INSTALLING THE REGULATOR INDOORS,
THE REGULATOR'S VENT MUST BE VENTED OUTDOORS USING VENT
LINE NO SMALLER THAN VENT OPENING.
VENT OF REGULATOR MUST
POINT DOWN AND REGULATOR
MUST BE VENTED OUTDOORS
OPTIONAL INDOOR
REGULATOR
MOUNTING LOCATION
GAS HOSE
THERMOSTAT
CORD
YOKE
1 FT.
THERMOSTAT
Guardian LP or Natural Gas Heater
CHAIN
CASE TOP
MANUAL SHUT-OFF VALVE
CAN BE INSTALLED BEFORE
THE REGULATOR, UNDER
THE EAVE OF THE BUILDING,
OR AFTER THE REGULATOR
INSIDE THE BUILDING.
BLACK PIPE
THROUGH WALL
VENT LINE
WALL OUTLET
HEATER
POWER CORD
SEDIMENT
TRAP
1 FT.
Owner's Manual • Guardian

Sediment Trap Assembly

Assemble the tee, nipples and cap together and
tighten securely. See Fig. 4. The sediment trap
assembly must always be mounted in a vertical
position. Make sure pipe thread compound that is
resistant to both L.P. gas and natural gas is used in
making all connections. Check all connections for
gas leaks using approved gas leak detectors.
FIG. 4
NIPPLE
TO GAS CONTROL
VALVE INLET
11