Installation Procedure
Wiringadiagram
Indoor unit terminal
block
Outdoor unit
terminal block
Power supply
1PH, 220-240V~, 50/60Hz
The specification of cable between indoor unit to outdoor unit is HO5RN-F4G 2.5mm
WARNING
y The power cable and connecting cable are self-provided.
y Always use a special branch circuit and install a special receptacle to supply power to the room air conditioner.
y Use a circuit breaker and receptacle matched to the capacity of the room air conditioner.
y The circuit breaker is installed in the permanent wiring. Always use a circuit that can trip all the poles of the wiring and has an
isolation distance ofat least 3mm between the contacts of each pole.
y Perform wiring work in accordance with standards so that the room air conditioner can be operated safely and positively.
y Install a leakage circuit breaker in accordance with the related laws and regulations and electric company standards.
CAUTION
y The power source capacity must be the sum of the room air conditioner current and the current of other electrical appliances.
When the current contracted capacity is insufficient, change the contracted capacity.
y When the voltage is low and the air conditioner is difficult to start, contact the power company the voltage raised.

FRESH AIR INTAKE

1. Open up the knockout hole for the fresh air intake. If using half-concealed
installation, open up the top knockout hole instead.
CAUTION
y When removing the cabinet (iron plate), be careful not to damage the indoor
unit internal parts and surrounding area (outer case).
y When processing the cabinet (iron plate), be careful not to injury yourself with
burrs,etc.
2. Fasten the round flange (optional) to the fresh air intake. If using half-
concealed installation, attach to the top.
3. Connect the duct to the round flange.
4. Seal with a band and vinyl tape,etc. so that air does not leak from the
connection.
R S T N
Indoor unit
terminal block
380-400V, 3N~,50/60Hz
2
29
1 2 3
Outdoor unit
terminal block
1 2 3
Y/G
Power supply
For half-concealed
Round duct (option part)
Y/G
Y/G