SRD Specifications
Capacity Range:
Maximum Arresting Force:
Average Arresting Force:
Maximum Arrest Distance:
*Assumes the SRD is mounted directly above the user.
Minimum Fall Clearance Required:
*Assumes the SRD is mounted directly above the user.
Maximum Free Fall:
*SRD must be mounted above user's D-ring.
SRD-LE Specifications
Capacity Range:
Maximum Arresting Force:
Average Arresting Force:
Maximum Arrest Distance:
*Assumes the SRD is mounted directly above the user.
Minimum Fall Clearance Required:
Maximum Free Fall:
*SRD must be mounted above user's D-ring.
Maximum Free Fall - LE:
*Measured from user's D-ring to working surface.
Table 1 – Specifications
ANSI Models
130 lb. - 310 lb. (59 kg - 140 kg)
1,350 lbf (6 kN)
900 lbf (4 kN)
42 in (1.1 m)
6 ft (1.8 m)
2 ft (0.6 m)
ANSI/OSHA Models
130 lb. - 310 lb. (59 kg - 140 kg)
1,350 lbf (6 kN)
900 lbf (4 kN)
42 in (1.1 m)
Vertical: 6 ft. (1.8 m)
Horizontal: 16.5 ft. (5.03 m)
2 ft (0.6 m)
5 ft (1.5 m)
12
OSHA Models
310 lb. - 420 lb. (140 kg - 191 kg)
1,800 lbf (8 kN)
N/A
42 in (1.1 m)
6 ft (1.8 m)
2 ft (0.6 m)