UK
1
GENERAL
SANIMARIN® MAXLITE+ is a WC
equipped with a pump/macerator
which installed and used correctly will
give reliable and consistent service for
many years. SANIMARIN® MAXLITE+
is for marine or mobile unit use. Please
follow these installation instructions,
paying attention to the following war-
nings :
Possible danger to personnel,
Warning of possible electrical hazard,
«WARNING» Possible danger of da-
mage to the macerator.
Read the user manual carefully before
using your appliance for the first time.
Incorrect use or installation releases
SFA from any liability.
This device is not designed
for persons (including children) with
limited physical, sensory or mental
abilities, or those with minimal expe-
rience and knowledge, unless they are
monitored and are given the necessary
instructions for using the device, with
the help of a person responsible for
their safety. Monitor children and make
sure they do not play with the device.
- To avoid electrical hazards and risks
of cuts never dismantle the appliance.
- Connection errors (observe the po-
larity) or incorrect use invalidate the
warranty.
- Don't use your appliance if a cable or
connection plug is damaged. To avoid
danger, have repairs done by autho-
rised persons.
- Never touch moving parts.
For further information, don't hesitate
to contact our customer service.
2
DESCRIPTION
SANIMARIN MAXLITE+ is a bowl fitted with a pump/
macerator to remove the sanitary effluent. It is also fitted
with a self-priming sea water supply pump.
Component materials:
• Copolyester bowl (very strong).
• Polyamide base.
Livret MAXLITE 2018.indd 4
3
TECHNICAL DATA
Pumping height: .............................3 m
Horizontal pumping distance: ..........30 m
Supply voltage : ...............................12V or 24V
Outlet diameter: ..............................38 or 25mm
Weight: ...........................................8 kg
4
OPERATING PRINCIPLE
SANIMARIN® MAXLITE+ is controlled by a two-po-
sition switch:
• Add water: bowl flushing command
• Pump out: maceration and discharge command.
5
USE
1/ FLUSH: (Add Water) recommended water level:
halfway up the bowl
2/ DISCHARGE: (Pump out)
3/ FLUSH: (Add Water) to refill the trap in WC pan
Note 1: In rough seas, empty the bowl (using the pump
out position) to avoid spillage
CAUTION 1
This product should not be used for any other purpose
other than that described here.
SANIMARIN® MAXLITE+ can be used like any normal
toilet and doesnot require any particular maintenance.
Only the disposal of toilet paper, fecal matter,
and waste water will be under guarantee. Any
damage due to foreign bodies such as cotton,
condoms, sanitary towels, wet wipes food, hair, or
liquids such as oils, solvent products,... will not be
under guarantee.
CAUTION 2
If away for a long period (holiday,...) or in the event
of a long interruption of electricity, the water and
electricity supplies to the SANIMARIN® should be
switched off.
CAUTION 3
Before you begin any work on this product,
make sure that all electrical power to the unit
has been switched off and that the through-hull
valves are in the CLOSED or STOP position.
6
FIXING THE DEVICE
Fix the MAXLITE+ securely using the screws
provided. The MAXLITE+ can be installed in place of
a toilet with a manual pump.
Your mountings must be appropriate for the base on
which the device is to be installed.
You can turn the MAXLITE+ bowl to suit
your requirements and the space available.
(see INSTALLATION INSTRUCTIONS 715)
FITTING THE ROCKER SWITCH
• Panel cut-out: rectangle 40 mm x 25 mm.
• Fitting the switch: Cut out a rectangle in the bulk-
head, to the measurements shown above.
• Fix the holder supplied in place with screws, and
then insert the switch.
4
7
EVACUATION
Caution : Please check local legislation regarding
discharge from on board toilets- i.e. holding tanks
etc.
SANIMARIN MAXLITE+ macerates and pumps
effluents. A seacock 3 should be fitted where the
SANIMARIN® discharges through a skin fitting.
Caution : For units installed below the water
line, the discharge pipe should rise at least 50 cm
above water level and be fitted with an anti-syphon
valve prior to falling and discharging through the
skin fitting.
The device outlet is fitted with a non-return valve.
(see NSTALLATION INSTRUCTIONS 715) (Exhibit G).
The outlet diameter is 38 mm (if necessary an adap-
ter for 25 mm is provided in the accessory bag).
8
CONNECTING THE SEA
WATER SUPPLY
First determine whether the sea water supply to
the MAXLITE+ will be above or below the water-
line, and then proceed with the INSTALLATION
INSTRUCTIONS 715.
If the installation of the toilet requires the use of
through-hull valves below the waterline, it is essen-
tial to follow the fitting instructions provided by the
manufacturer of the through-hull valve. Access to
the valves should be easy for all users of the toi-
let. If this is not the case, additional full flow marine
quality valves should be installed on the water inlet
and outlet.
If the toilet is connected to a through-hull fitting
below the waterline, it is important to check the
condition of the pipes. There is a risk of water entry
into the boat, which could cause it to sink. Use of a
vented loop is mandatory.
Caution: all vented loops (not supplied with the
toilet) must be installed a minimum of 50 cm above
the waterline.
When using for the first time, it may be necessary to
prime the pump by pouring a little water into it.
Connect your water feed pipe from the through-hull
valve to the built-in self-priming pump (20 mm dia.).
Fit necessarily a filter upstream of your
installation.
CAUTION: Do not connect the MAXLITE+ Toilet to an
on-board drinking water or pressurised water system.
Do not install a pump controlled by an automatic
switch.
Failure to comply with the above guidelines could
cause a flood or contamination of the drinking water
supply.
Make sure that the two through-hull fittings: those
for the sea water supply and for the soil water outlet
are not too close together.
09/04/2018 16:29