EN
Fully illustrated step by step
instructions are downloadable
on www.saniflo.co.uk
1
DESCRIPTION
SANICOMPACT
Star /SANICERAMIC 3
®
wall hung WC pan fitted with a pump macerator .
Star /SANICERAMIC 3
The SANICOMPACT
®
can only be installed with the special support
brackets supplied. SANICOMPACT
SANICERAMIC 3
is for use in a domestic
®
environment.
Installed and used correctly, SANICOMPACT
Star /SANICERAMIC 3
will give reliable and
®
consistent service.
Please note the following warning signs:
"
" Possible danger to personnel,
"
" Warning of possible electrical hazards,
"WARNING" This is a general warning that
failure to follow instructions could result in
poor functioning of the unit.
PRINCIPLES OF OPERATION
SANICOMPACT
Star /SANICERAMIC 3
®
controlled by an electronic program with two
functions.
• The cycle which is activated by pressing
the flushing button on the pan. The
macerating/pump cycle takes 25 seconds.
• The pumping only cycle cleans the
washbasin waste. This is an automatic
operation that will activate as long as water
from the washbasin enters the unit.
2
LIST OF ACCESSORIES SUPPLIED
3
DIMENSIONS
4
TECHNICAL DATA
évacuation WC
Applications
évacuation lave-mains
Type
Maximum Vertical Pumping
Voltage
Frequency
Normal Power Rating
Maximum current consumption 2,5 A
Medium water temperature
Electric Class
Degree of protection
Net Weight (with frame)
WARNING:
Only installations conforming to
the above specifications are acceptable.
5
PERFORMANCE CURVE
6
VERTICAL/HORIZONTAL
PUMPING COMBINATIONS
7
INSTALLATION
PREPARATIONS
WARNING:
Before proceeding with the
installation of SANICOMPACT
®
SANICERAMIC 3
, ensure that the wall is
®
sufficiently robust to support the unit. (Each
fixing should have a tensile strength of 120 kg).
HANGING THE PAN ONTO THE
7a
SUPPORT FRAME
1 -
Separate the pan and template
the frame (screwed together for transit
purpose).
2
- Assemble the threaded rods
and washers
B
is a
®
3
- Adjust the rod position to 50 mm + x the
wall thickness (eg. Stud partition and
®
tiles etc). See drawing 7a.
4 -
Adjust the lateral spacing of the rods.
Star /
®
5 -
Tighten the nuts fully.
6 -
Fit the plastic sleeves/inserts
the threaded rods. (They protect the
®
ceramic from the metal threads).
SETTING THE HEIGHT OF THE
7b
SUPPORT FRAME
1
- Offer the frame and pan up to the wall.
2
- Adjust to a comfortable height using the
vertical threaded feet. (See drawing 7b).
3 -
Remove the pan from the frame.
is
®
4
- Adjust the horizontal seating of the pan
support.
5
- Fully tighten the rod nuts.
FIXING THE FRAME TO THE WALL
7c
1 -
Offer the support frame up to the wall.
2 -
Ensure the seating is correct.
3
- Mark the screw holes with a pencil.
4
WARNING:
-
vertical, use the six holes with a suitable
combination of packing/washers (as per
drawing 7c).
5 -
Select the fixing appropriate for the
particular wall (we recommend minimum
size 8 x 120 mm wall fixings).
6
- Drill holes with appropriate drill.
C45
3 m
7
- Fix the frame to the wall using the 4 or
220-240 V
6 holes accordingly.
50 Hz
8
-
WARNING:
500 W
The distance between the supporting
35°C
wall and the front of the support frame
should not exceed 100 mm.
I
IP44
Most importantly, the frame and the wall
28 Kg
should make a completely snug fit.
WATER SUPPLY
7d
1 -
Run the water supply with copper pipe
in 15 mm, fitted with a 22 mm male iron
to connect to the SANICOMPACT
Star /SANICERAMIC 3
2 -
The water supply pipe must be fitted in
the upper part of the frame.
3 -
WARNING:
isolation valve when fitting the pan.
4 -
For correct rinsing of the bowl, the water
pressure entering the pan must be
Star /
minimum 1,7 bar.
from
E
with nuts
A
as per drawing 7a.
C
onto
D
If your wall is not perfectly
®
.
®
It is essential to install an
8
DISCHARGE CONNECTION
7e
1 -
The discharge pipe should be either
copper or UPVC solvent weld pipe with
32 mm diameter.
2 -
Put the end of the pipe through the
upper part of the frame.
If the discharge pipework runs to a level
3 -
considerably lower than SANICOMPACT
Star /SANICERAMIC 3
unit, the resultant
®
syphoning effect can suck out the water
seal in the unit. Fitting an air admittance
valve
(BBA approved) at the high point of the
pipe run will overcome this problem.
CONNECTION OF WASH-BASIN
7f
1 -
Connect washbasin waste via 32 mm or
40 mm CPVC pipe.
2 -
Feed the waste pipe through either the
left or right hand holes provided.
3 -
IMPORTANT:
The waste pipe should
terminate in 40 mm to connect to the
special connector provided.
7g ELECTRIC POWER SUPPLY
The electrical installation work must be car-
ried out by a qualified person.
The electrical installation work for the
equipment, in a bathroom, must be carried
out in accordance with the standards in force
in the country (NF C 15-100 in France).
The electric power supply as wired
beforehand by the installer must be class 1,
using 3 X 0.75 sq. mm wiring.
1 – Connect the electric power supply to a
triple screw connector (not supplied) in
an
IP55 junction box (Sarel 01650 or
similar) installed beforehand, complying
with the following colours:
Brown = phase
Blue = neutral
Green/Yellow = earth.
2 – This connection must be used solely to
power the equipment, and it must be
protected by a high sensitivity 30mA
differential circuit breaker, set at 16 A.
3 -
ATTENTION:
the electrical junction box
must remain accessible after installation
of the toilet.
®