Specifications; Generator Specifications: 12Kw; Engine Specifications - Briggs & Stratton 12kW Manual De Instalación Y Operación

Generador de reserva monofasico enfriado por aire
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Specifications

Generator Specifications: 12kW

Rated Maximum Load Current* (at
25°C/77°F, LP)*: at 240 Volts
Rated AC Voltage
Phase
Rated Frequency
Generator Breaker
Normal Operating Range
Output Sound Level
Shipping Weight
* Natural gas rating will depend on specific fuel but typical
derates are between 10 to 20% of the LP gas rating.

Engine Specifications

Displacement
Bore
Stroke
Spark Plug Gap
Spark Plug Torque
Armature Air Gap
Intake Valve Clearance
Exhaust Valve Clearance 
Oil Type
Oil Capacity (with filter)
50 Amps
120/240 Volts
Single phase
60 Hertz
60 Amp
-20°F (-28.8°C) to 104°F (40°C)
72.3 dB(A) at 23 ft. (7 m) at normal
load
318 lb (144 kg)
38.26 ci. (627 cc)
2.972 in. (75.5 mm)
2.756 in. (70 mm)
0.020 in. (0.51 mm)
180 lb-in. (20 Nm)
0.008 - 0.012 in. (0.20 - 0.30 mm)
0.004 - 0.006 in. (0.10 - 0.15 mm)
0.007 - 0.009 in. (0.18 - 0.23 mm)
5W30 Synthetic
42 - 45 oz. (1.24 - 1.33 L)
41