GYS Tool it PBT 824 Manual De Usuario página 10

Ocultar thumbs Ver también para Tool it PBT 824:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
Translation of the original instructions
Customise
BATTERY TEST
1. Select «Battery Test» from the main menu and press «ENTER»
2. Press
to select «REGULAR / STANDARD» or «START / STOP»
3. Press button
5. Press the
key to select the standard (EN, CCA, BCI, CA, MCA, JIS, DIN, IEC, SAE, GB)
6. Press the
button to enter the battery capacity (shown in Ah-hour amp)
7. Confirm the ambient temperature above 0 ° (32 ° F) by pressing «ENTER».
8. Follow the instructions of the tester.
At every steps, it is possible to return to the main menu by pressing «ENTER» for 2 seconds.
Battery test result
The result screen turns green, orange or red depending on the result found. Green indicating a positive result, orange good but
to be watched, red to be replaced.
Result
Battery in good condition
Good condition, to be recharged
Warning
Charge & test
To replace
Defective cells to replace
Charge error
Display of the state of charge and the state of health of the battery
1. Press the directional buttons to view the SOC (charge status) and SOH (health status) of the battery.
2. Select YES or NO using the arrow keys to print the result and press «ENTER».
3. Press «ENTER» to return to the main menu.
10
to select the battery type. Press «ENTER» to confirm.
CCA : xxxx CCA/SAE
CCA : xxxx CCA/SAE
CCA : xxxx CCA/SAE
CCA : xxxx CCA/SAE
CCA : xxxx CCA/SAE
CCA : xxxx CCA/SAE
CCA : xxxx CCA/SAE
PBT 824
CUSTOMISE
Results found
VOL : xx.xx V
IR : xx.xx mΩ
BATTERY OK
VOL : xx.xx V
IR : xx.xx mΩ
OK TO RECHARGE
VOL : xx.xx V
IR : xx.xx mΩ
WARNING
VOL : xx.xx V
IR : xx.xx mΩ
CHARGE & TEST
VOL : xx.xx V
IR : xx.xx mΩ
TO REPLACE
VOL : xx.xx V
IR : xx.xx mΩ
CEL DEF. TO REPLA
VOL : xx.xx V
IR : xx.xx mΩ
ERROR CHARGE
Press ""ENTER"" to edit the custom
information.
Analysis
The battery is operational.
Battery in good condition but low current.
To recharge before any use.
The battery must be maintained. It gradually
weakens the starting capacity of the engine.
There may also be a bad connection between the
vehicle and the battery. Monitor the battery for a
possible replacement.
The battery discharges quickly and is no longer
functional. Replace the battery.
The battery discharges quickly and is no longer
functional. Replace the battery.
At least one of the cells in the battery is in
short-circuit. Replace the battery.
The battery exceeds 2,000 CCA or 200 Ah, or the
clamps are not connected properly. Fully charge
the battery and retest after discarding the other
two causes. If the display remains the same, the
battery must be replaced.