STORAgE
CAUTION: Disconnect heater
from propane/LP supply cylinder.
1. Do not store heater while attached to
propane/LP cylinder. Close cylinder valve.
Remove the hose/regulator assembly
from the propane/LP cylinder by turning
the fuel gas connector nut clockwise.
2. Storage of heater inside is permissible
only if the cylinder is disconnected and
removed from the appliance.
3. Store propane/LP cylinder in safe manner.
Refer to Chapter 5 of Standard for Storage
and Handling of Liquefied Petroleum Gases,
ANSI/NFPA 58. Follow all local codes.
Cylinders must be stored outdoors in a
well-ventilated area out of reach of children.
Disconnected cylinders must have threaded
valve plugs tightly installed, and must not be
stored in a building, garage or any other en-
closed area. Never store cylinders near high
heat, open flame, or where temperatures
exceed 100° F (38° C).
4. Store in a dry, clean, and safe place.
• Rating: High - 16,000 Btu/Hr (4.69 kw)
Low - 9,500 Btu/Hr (2.78 kw)
• Fuel: Propane Vapor Only
• Fuel Consumption/Hour: Min. 0.10 gal (0.39 liter), Max. 0.17 gal (0.66 liter)
Min. 0.44 lb (0.20 kg), Max 0.74 lb (0.33 kg)
• Supply Pressure (To Regulator): Maximum - 200 psi (1,379 Kpa)
Minimum, for input adjustment - 5 psi (34.5 Kpa)
• Manifold Pressure: High - 11 WC (2.74 kPa), Low - 10.6 psi (73.08 kPa)
• Ignitor Gap: 0.120"
• Minimum Temperature: -20°F (29°C) Surrounding Air Temperature
• Heater Size (L x W x H): 30.5" x 30.5" x 43.5" (0.77 x 0.77 x 1.1 m)
• Carton Size (L x W x H): 25.75" x 25.75" x 16.25" (0.65 x 0.65 x 0.41 m)
• Heater Weight: 73 lb (33.1 kg)
• Shipping Weight: 84 lb (38.1 kg)
118992-01F
service heater while it is con-
nected to propane/LP supply,
operating, or hot. Severe burns
can occur. Any guard or other
protective device removed for
servicing must be replaced prior
to operating the heater.
1. Keep heater clean. Remove any debris
2. Inspect heater before each use. Check
3. Inspect hose/regulator assembly before
4. Spiders and insects can create a danger-
5. Have heater inspected yearly by a quali-
SPECIFICATIONS
www.desatech.com
MAINTENANCE
WARNING: Never attempt to
from ventilation openings.
connections for leaks. Apply mixture of
liquid soap and water to connections.
Bubbles forming show a leak that must
be corrected. Correct all leaks at once.
each use. If hose is highly worn or cut,
replace it immediately. At least annually,
remove hose/regulator assembly from
heater to inspect entire length of hose.
ous condition that may damage heater or
make it unsafe. Keep burner area clean
of all spiders, webs, or insects.
fied service person.