Thermador SGS Manual Del Usuario página 8

Ocultar thumbs Ver también para SGS:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

English 6
Figure 5 - Rough-in Box Area
CAUTION:
Do not attempt any adjustment of the pressure regulator,
except conversion to propane.
Connect the gas supply line to the unit pressure regulator using a 1/2" flex gas line
connector between wall shut-off valve and pressure regulator.
Figure 6 - Gas and Electrical Location
Pressure
Regulator
Shows
Direction of
Gas Flow
Secure regulator to cooktop gas inlet using approved Teflon tape. Turn to hand
tighten plus 1/4 turn, not exceeding 1 turn for alignment.
Check supply line connections for leaks using a soap solution. Do not use a flame
of any sort.
1. Turn on gas.
2. Apply a non-corrosive leak detection fluid to all joints and fittings in the gas
connection between the shut-off valve and the range. Include gas fittings and
joints in the range if connections may have been disturbed during installation.
Bubbles appearing around fittings and connections indicate a leak.
3. If a leak appears, turn off supply line gas shut-off valve and tighten connec-
tions.
4. Retest for leaks by turning on the supply line gas shut-off valve. When leak
check is complete (no bubbles appear), test is complete.
5. Wipe off all detection fluid residue.
Important Notes for Gas Connection:
The appliance and its individual gas shutoff valve must be disconnected from
the gas supply piping system during any pressure testing of that system at
test pressures in excess of 1/2 psig (3.5kPa).
The appliance must be isolated from the gas supply piping system by closing
its individual manual shut-off valve during any pressure testing of the gas sup-
ply piping system at test pressures equal to or less than 1/2 psi (3.5kPa).
Opening for Gas
Connection and
Electrical Cord
C of Cutout
L
for 30" models - 12-15/16" (312.8 mm)
for 36" models - 15-15/16" (389 mm)
for 45" models - 20-3/8" (30 mm)
Rough-in Box
1/2"
Female Pipe
Threads
Supply Cord
120 V
C of Wall
L
Flex Gas Line
Gas Shut-Off Valve
Cabinet Floor
Gas Stubout
Receptacle
Tabla de contenido
loading

Este manual también es adecuado para:

Sgsx

Tabla de contenido