Symptoms
The pump is not working or there is no oil
delivery.
The pump begins to operate very fast.
The pump keeps on operating although
the oil outlet is closed.
Oil leakage through the air outlet muffler.
Air leakage through the air outlet muffler.
Diminution of the oil delivery.
The pump operates one cycle and stops.
E
Síntomas
La bomba no funciona o no hay entrega
de aceite.
La bomba empieza a bombear mucho
más deprisa.
La bomba sigue funcionando aunque se
cierre la salida de aceite.
Perdida de aceite por el silenciador del
escape de aire.
Perdida de aire por el silenciador del esca-
pe de aire.
Disminución de caudal entrega de aceite.
La bomba empieza funcionar, pero para
después de un ciclo.
4
834 811 R.06/14
Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533
Operation/ Modo de empleo
Esta bomba es auto-cebante. Para cebarla la primera vez, es
conveniente conectar el aire a la bomba incrementando la presión
lentamente desde 0 bares a la presión deseada con el regulador de
presión, manteniendo la válvula de salida (Ej. una pistola de aceite)
abierta. Cuando el aceite empieza salir de la pistola/ las pistolas, la
bomba está cebada.
NOTA: Es importante que la válvula de pie no esté en contacto con
zonas sucias, tales como el suelo de un taller, porque puede entrar
virutas o partículas que podrían llegar a dañar las juntas.
Troubleshooting/ Anomalías y sus soluciones
Possible Reasons
Not enough air supply pressure.
Some outlet line component is clogged or
closed.
The drum/tank is empty or the oil level is
beneath the suction tube inlet.
There is an oil leakage in some point of the
outlet circuit.
Impurities in the upper valve or in the foot
valve (fig. 6-7).
Oil has by-passed to the air motor caused by
worn or damaged packing set (735210).
The piston seal (946503) is worn or damaged.
The air motor dolly is scratched.
The air piston rod (734224) is scratched.
The reversing set (734616) is worn or damaged.
Impurities in the upper valve or in the foot
valve (fig. 6-7).
The top reversing spring (835302) is damaged.
Posibles causas
Presión de suministro de aire no adecuada.
Algún elemento del circuito de salida está
obstruido o cerrado.
El bidón esta vacío o el nivel de la aceite esta
por debajo de la entrada de la bomba.
Existe fuga de aceite en algún punto del cir-
cuito de salida.
Suciedad en la válvula superior o en la vál-
vula de pie (fig. 6-7).
Aceite ha pasado al motor de aire causado
por deterioro del conjunto empaquetadura
(735210).
El collarín del vástago (946503) está deteriorado.
La cazoleta del motor de aire está rayada.
El vástago (734224) está rayado.
El conjunto inversor (734616) desgastado.
Suciedad en la válvula superior o en la vál-
vula de pie (fig. 6-7).
Rotura del muelle inversor superior
(835302).
E
Increase the air supply pressure.
Clean or open the outlet circuit.
Replace the drum/fill the tank or lower the
suction tube until the inlet reaches the oil level.
Verify and tighten or repair.
Dismount and clean. Replace in case of
damage.
Replace the packing set.
Dismount and clean. Replace in case of damage.
Replace air motor dolly.
Replace the piston rod.
Replace the reversing set.
Dismount and clean. Replace in case of
damage.
Replace the top reversing spring.
Incremente la presión de suministro de aire.
Limpie o abra el circuito de salida.
Sustituir el bidón o calar el tubo de succión
hasta llegar al nivel del aceite.
Verificar y apretar o reparar.
Desmontar y limpiar las válvulas. En caso de
deterioro, sustituirlas.
Sustituir el conjunto empaquetadura .
Sustituir el collarín del vástago.
Sustituir la cazoleta.
Sustituir el vástago.
Sustituir el conjunto inversor.
Desmontar y limpiar las válvulas. En caso de
deterioro, sustituirlas.
Sustituir el muelle inversor superior.