tion. If more than six PULSE 160 units are to be in-
tegrated into a housing unit, a second independent
control must be added.
The PULSE CONTROL 160 can be placed anywhe-
EN
re. Connection cables must be 3 poles, it is re-
commended that a LiYY data cable be used. To
ensure an adequate power supply, the length of
the cable from the control to the fan unit must not
exceed 100m. Example of six-unit wiring PULSE
160.
4.4. CONNECTION AND WIRING
Warning: Incorrect pin assignment may damage
the fan unit.
All electrical installations must be approved by an
suitably qualifi ed person. It is important to ensure
that all connections comply with regulations.
Fan 1
Fan 2
To connect the PULSE CONTROL 160 to the PULSE
160 units you must use a 3-pin connector of 3.5
mm between cables.
5. INSTALLATION
5.1. MAKING THE HOLE IN THE WALL
Depending on how the unit is to be
installed please follow either the
instructions for the use of a pre-
fabricated installation block or for
core-drilling a hole through the wall.
18
Fan 3
Fan 5
Black
Power
adapter
Red
Fan 6
Fan 4
5.1.1. Use of a core-drilled hole
Drill a hole in the wall using a core drill and a 162
mm bit. The hole must have a gradient of 1–3°,
allowing any condensate to fl ow outwards. It is
best to drill the hole from inside to outside.
INSIDE
When core drilling, please make
sure that there is adequate protec-
tion from falling masonry on the out-
side of the building, ensuring that no
person or material will be harmed/
damaged.
5.2. INSERTING THE MOUNTING TUBE
When using a special solution, plea-
se refer to its specifi c instructions.
OUTSIDE