Make Gas Connection
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
1. Assemble flexible connector from gas supply pipe to
pressure regulator located in the middle rear of the range.
2. Apply pipe-joint compound made for use with Propane gas
to the smaller thread ends of the flexible connector adapters.
(See B and G in the following illustration.)
3. Attach one adapter to the gas pressure regulator and
the other adapter to the gas shut-off valve. Tighten both
adapters, being certain not to move or turn the gas pressure
regulator.
4. Use a 15/16" (2.4 cm) combination wrench and an adjustable
wrench to attach the flexible gas supply to the adapters.
Check that connector is not kinked.
IMPORTANT: All connections must be wrench-tightened.
Do not make connections to the gas regulator too tight. Making
the connections too tight may crack the regulator and cause a
gas leak. Do not allow the regulator to turn or move when
tightening fittings.
A
B C
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have 1/2"
[1.3 cm] male pipe thread)
D. Flexible connector
D
E
H
G
F
E. Manual gas shut-off valve
F. 1/2" (1.3 cm) or
3/4" (1.9 cm) gas pipe
G. Use pipe-joint compound.
H. Adapter
Complete Connection
1. Open the manual shut-off valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A
A. Closed valve
B. Open valve
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles
appear, a leak is indicated. Correct any leak found.
3. Remove range burner caps, and grates from parts package.
Place burner caps on burner bases. Place grates over
burners and caps.
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
4. Plug into a grounded 3 prong outlet.
5. Turn on power supply. For further information, please refer
to the user instructions located in the Use and Care Guide.
Verify Anti-Tip Bracket Location
1. Using a 5/16" (7.9 mm) socket or wrench, turn all four
leveling rods one full turn to raise the range and provide
enough clearance for the rear leveling leg to slide into the
anti-tip bracket.
2. Move range into its final location, making sure rear leveling
leg slides into anti-tip bracket.
3. Use a flashlight to look underneath the bottom of the range
and visually check that the rear range foot is inserted into
the slot of the anti-tip bracket.
B
13