BURNER DESCRIPTION
Two stage progressive operation mode or fully modulating by regulator, available as accessory.
The burner is approved for intermittent operation as per Directive EN 676.
The burner meets protection level of IP 40, EN 60529.
According to Directives: EMC 2004/108/EC, Low Voltage 2006/95/EC and Machines 2006/42/EC.
Gas train according to EN 676.
1 - Air damper servomotor
2 - Air-damper
3 - 6 pole socket for gas-train
4 - 7 pole socket for electrical
controls
5 - 4 pole socket for high-low power
6 - Power regulator of RWF 40
7 - Grommet
8 - Lock-out lamp and reset button
9 - Screw for fixing the cover
11 - Max. air pressure switch
NOTE
The cable grommet (7) and the screw for fixing the cover (9) supplied with the burner, must be fitted to the
same side as the gas train.
1.1 BURNER EQUIPMENT
Flange with insulating gasket . . . . No. 1
Screw and nut for flange . . . . . . . . No. 1
Hinge . . . . . . . . . . . . . . . . . . . . . . No. 1
Screw for fixing the cover . . . . . . . No. 1
Cable grommet . . . . . . . . . . . . . . . No. 1
Pipe . . . . . . . . . . . . . . . . . . . . . . . No. 1
1
1
2
5.
2
2
2
3
4
4
5
6.
6
6
7.
FAULTS / SOLUTIONS . . . . . . . . . . . . . . 12
6
8
11
4
9
10
7
Screws and nuts for flange to be fixed to boiler . . . . No. 4
7 pin plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No. 1
4 pin plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No. 1
6 pin plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . No. 1
M12 connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . No. 1
G1/8 union elbow . . . . . . . . . . . . . . . . . . . . . . . . . . No. 1
1
GB
Fig. 1
5
3
1
D4021
2
20067072