7

Operation

Warning
• Make sure that:
– Nobody can reach into the swivel range of the moving mass
– And that no objects can get there (e.g. by means of a self-made protective
screen).
For several uninterrupted swivel cycles:
Make sure that the maximum permitted swivel frequency is not exceeded
(
Technical data).
Otherwise, the functional reliability will be impaired by excessive heating.
To extend the service life of the shock absorbers:
Apply a thin coat of grease to the stop caps of the shock absorbers.
To check the functions:
Check the shock absorbers for oil loss after every 2 million switching cycles.
Replace shock absorbers with visible oil loss or at the latest every 5 million
switching cycles (
8

Care and maintenance

In case of contamination, clean the product with a soft cloth.
All non-abrasive cleaning agents are permitted (e.g. warm soap suds up to
+60 °C).
Festo DSMI-...-B 1210b English
Accessories).
39