LOGICS WITH MICROPROCESSOR
STATUS OF INPUTS SIGNALLED BY LEDs
"PEDESTRIAN GATE" FUNCTION
INCORPORATED FLASHING CIRCUIT
• ENCODER SENSOR FOR OBSTACLE DETECTION AND SELF-LEARNING OF TRAVEL
RECEIVER CONNECTOR
BATTERY CONNECTOR
• BATTERY CHARGER BOARD (INTEGRATED)
DIAGNOSTICS OF MALFUNCTIONS SIGNALLED BY LED
When you have completed the connection:
 All the green LS LEDs must be on (each of them corresponds to a Normally Closed input).
The go off only when the controls to which they are associated are operated.
 All the red LS LEDs must be off (each of them corresponds to a Normally Open input). The
light up only when the controls to which they are associated are operated.
Before proceeding, make sure the mechanical components work correctly. Also check
that the gear motor assembly has been installed according to the instructions. Then
make sure that the power consumption of the gear motor is not greater than 3A (other-
wise the control panel may not work properly).
THE EQUIPMENT MUST BE INSTALLED "EXPERTLY" BY QUALIFIED PERSONNEL AS RE-
QUIRED BY LAW.
NB : it is compulsory to earth the system and to observe the safety regulations that are
in force in each country.
IF THESE ABOVE INSTRUCTIONS ARE NOT FOLLOWED IT COULD PREJUDICE THE
PROPER WORKING ORDER OF THE EQUIPMENT AND CREATE HAZARDOUS SITUA-
TIONS FOR PEOPLE. FOR THIS REASON THE "MANUFACTURER" DECLINES ALL RE-
SPONSIBILITY FOR ANY MALFUNCTIONING AND DAMAGES THUS RESULTING.
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to avoid
breakdowns of the line and false contacts;
-
do not re-use old pre-existing cables<
-
we recommend to use the TAU cable code M-03000010C0 to connect the motors to the
control board.
Board power supply
Max motor power DC
Fast acting fuse for protection of input power supply 13.5 Vac (F1 - 5x20)
Fast acting fuse for motor protection (F2 - 5x20)
Fast acting fuse for protection of auxiliary circuits 18 V dc (F3 - 5x20)
Fast acting fuse for protection of battery (F4 - 5x20)
Motor power supply circuits voltage
Auxiliary device circuits supply voltage
Logic circuits supply voltages
Operating temperature
CONTROL BOARD FOR MASTER12Q GEARMOTOR
K123M

TECHNICAL CHARACTERISTICS

English
TESTING
INSTALLATION
13,5 Vac - 50 Hz
50 W - 18 Vdc
F 15A
F 15A
F 1,6A
F 10A
18 Vdc
18 Vdc
5 Vdc
-20 °C ÷ +70 °C