CONTROL PANEL FOR 230 Vac SINGLE-PHASE MOTOR
•
MICROPROCESSOR-CONTROLLED LOGIC
•
INPUT STATUS LED'S
•
LINE INPUT FUSE
•
BUILT-IN FLASHING LIGHT CIRCUIT
•
"MAN PRESENT" FUNCTION
•
ELECTRIC BRAKING
•
WEEKLY TIMER INPUT
•
MOTOR TORQUE CONTROL AND OBSTACLE DETECTION BY MEANS OF ENCODER
•
433.92 MHz 2 CHANNEL BUILT-IN RADIO RECEIVER (CH)
•
CONTROL OF THE SENSITIVE EDGE
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to
avoid breakdowns of the line and false contacts.
-
do not re-use old pre-existing cables.
TESTING
When all connections have been made:
•
All the green LS LED's must be on (each corresponds to a Normally Closed input).
•
They only turn off when the commands they are associated with are active.
•
All the red LS LED's must be off (each corresponds to a Normally Open input) they only turn
on when the commands they are associated with are active.
TECHNICAL CHARACTERISTICS
Power input to board
Nominal power
Primary input line rapid fuse (F1 - 5x20)
Input voltage of motor circuits
Input voltage of auxiliary circuits
24Vac line rapid fuse (F2 - 5x20)
Logic circuit input voltage
Working temperature
Box protected to
DIAGNOSTICS LED
DL1 (STOP)
DL2 (PEDESTRIAN)
DL3 (STEP BY STEP)
DL4 (OPEN)
DL5 (CLOSE)
DL6 (SENSITIVE EDGE)
DL7 (PHOTOCELL)
DL8 (CLOSE LIMIT SWITCH)
DL9 (OPEN LIMIT SWITCH)
DL10 (RADIO CONTROLS)
14
STOP button green LED signal
PEDESTRIAN button red LED signal
STEP BY STEP button red LED signal
OPEN button red LED signal
CLOSE button red LED signal
SENSITIVE EDGE green LED signal
PHOTOCELL green LED signal
CLOSE LIMIT SWITCH green LED signal
OPEN LIMIT SWITCH green LED signal
RADIO CONTROLS programming red led
D705M
230V AC - 50÷60Hz
600 W ca.
F3,15A - 250V AC
230V AC
24V AC
F1,6A - 250V AC
5V DC
-20°C ÷ + 55 °C
IP43