All manuals and user guides at all-guides.com
15
IGNITION - OPERATION - SHUTDOWN INSTRUCTIONS
IGNITION
Open the gas tap and tun the selector switch (6) to the desired position. The burner will ignite automatically.
Should ignition fail to take place check the lock-out warning light (1) and fault warning light (3) to see if they
have come on. Turn the selector (6) to the reset position A. Then rotate the selector (6) again to the desired
position. Then adjust heating temperature (4) and hot water temperature (5) as desired via the appropriate
controls.
TEMPORARY IGNITION/SHUTDOWN
Proceed as follows:
● adjust the room thermostat;
● adjust the potentiometers on the front panel (4) (5).
PROLONGED SHUTDOWN
Should the boiler remain idle for a long period close the gas tap, position the selector switch (6) at position
(0) and disconnect the electrical power supply.
HEATER MODE
(IF ANY)
Turn the selector switch (6) to Heater position
Regulate the hot water potentiometer (5) to a position corresponding to desired water temperature.
HEATING/HEATER MODE
(IF ANY)
Turn the selector switch (6) to Heating/Heater position
Regulate the heating potentiometer (4) to a position that corresponds to desired room temperature.
If a room thermostat is installed then the thermostat will keep room temperature at the set level.
Adjust the hot water potentiometer (5) to a position corresponding to desired water temperature.
IMPORTANT:
The unit is fi tted with Flue Control to monitor fl ue draught. This safety device shuts down the boiler if there is a
risk of combustion fume backfl ow into the room. This device must never be deactivated. If combustion fumes
re-enter the room they may cause chronic or acute intoxication that can be fatal. If the Flue Control device
is changed use only original spare parts. If the device trips repeatedly check for proper fume outfl ow via the
chimney fl ue and contact a Lamborghini Service Centre.
WARNING: When Heater
or Heating/Heater
mode is selected the ON indicator light comes on
indicating that the boiler is electrically powered.
WARNING: Use only 2A/250VC - 5x20 rapid fuses.