700-Series Access Cover; Electrical Service And Operation - Liberty Pumps Pro370 Serie Manual De Instalación

Ocultar thumbs Ver también para Pro370 Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

QuickTree Settings for Vertical Discharge Pro370 and
Pro380-Series Systems
Table 1. Tether Length (Switch Position to Clamp)
Pro370-Series
Rod
Position
Alarm Float
Control Float
1
2
3.5"
3
4
When servicing the QuickTree, place the switch cord into the
trough or channel and then slip the stainless steel rod through the
clamp. Tighten the screw with a Phillips screwdriver, being careful
not to overtighten. Flats have been stamped on the rod to
designate float position, and the screw should be tightened onto
the flat. Tether length is the amount of cord between the clamp
and float.
P370-SERIES SHOWN
Float positions 1, 2, 3,
and 4 are identified by
flats stamped onto the
stainless rod. 1 is
highest; 4 is lowest.
1
2
4
TETHER LENGTH
Figure 12. QuickTree Example Settings

700-Series Access Cover

The 700-Series cover contains access to the float and alarm cord
entry/exit seals. Refer to Figure 8 for these locations.
QuickTree is not available on 700-Series systems. The pump
control float is attached to the pump while the alarm float is on
the discharge pipe.
– 8 –
Pro380-Series
Alarm Float
Control Float
3.5"
3.5"
ALARM FLOAT
3
(ON OPPOSITE SIDE)
PUMP CONTROL FLOAT
Copyright © Liberty Pumps, Inc. 2018 All rights reserved.

Electrical Service and Operation

WARNING
 Always disconnect pump(s) from power source(s) before
handling or making any adjustments to either the pump(s),
the pump system, or the control panel.
 All installation and maintenance of pumps, controls,
protection devices, and general wiring shall be done by
qualified personnel.
3.0"
 Do not remove cord and strain relief, and do not connect
conduit to pump.
 Pump shall be properly grounded using its supplied
grounding conductor. Do not bypass grounding wires or
remove ground prong from attachment plugs. Failure to
properly ground the pump system can cause all metal
portions of the pump and its surroundings to become
energized.
 Do not handle or unplug the pump with wet hands, when
standing on damp surface, or in water unless wearing
Personal Protective Equipment.
 Do not lift or carry a pump or a float assembly by its power
cord. This will damage the power cord, and could expose the
electrically live wires inside the power cord.
 The electrical power supply shall be located within the length
limitations of the pump power cord, and for below grade
installations, it shall be at least 4 ft (1.22 m) above floor level.
 Protect the power and control cords from the environment.
Unprotected power and control (switch) cords can allow
water to wick through ends into pump or switch housings,
causing surroundings to become energized.
WARNING
 Do not use an extension cord to power the product.
Extension cords can overload both the product and extension
cord supply wires. Overloaded wires will get very hot and can
catch on fire.
 This product requires a separate, properly fused and
grounded branch circuit, sized for the voltage and amperage
requirements of the pump, as noted on the nameplate.
Overloaded branch circuit wires will get very hot and can
catch on fire.
 Do not use this product with or near flammable or explosive
fluids such as gasoline, fuel oil, kerosene, etc. If rotating
elements inside pump strike any foreign object, sparks may
occur. Sparks could ignite flammable liquids.
 Sewage and effluent systems produce and may contain
flammable and explosive gases. Prevent introduction of
foreign objects into basin as sparks could ignite these gases.
Use caution using tools and do not use electronic devices or
have live, exposed electrical circuits in or around basins, open
covers and vents.
 These pumps are not to be installed in locations classified as
hazardous in accordance with the National Electric Code
ANSI/NFPA 70.
RISK OF ELECTRIC SHOCK
RISK OF FIRE
®
,
7225000I